This study evaluated the Knoop Hardness (KHN) values of two dual-cured composite resin core build-up materials and one resin cement exposed to different curing conditions. Two dual-cured core build-up composite resins (LuxaCore-Dual, DMG; and FluoroCore2, Dentsply Caulk), and one dual-cured resin cement (Rely X ARC, 3M ESPE) were used in the present study. The composite materials were placed into a cylindrical matrix (2 mm in height and 3 mm in diameter), and the specimens thus produced were either light-activated for 40 s (Optilux 501, Demetron Kerr) or were allowed to self-cure for 10 min in the dark (n = 5). All specimens were then stored in humidity at 37 degrees C for 24 h in the dark and were subjected to KHN analysis. The results were submitted to 2-way ANOVA and Tukey's post-hoc test at a pre-set alpha of 5%. All the light-activated groups exhibited higher KHN values than the self-cured ones (p = 0.00001), regardless of product. Among the self-cured groups, both composite resin core build-up materials showed higher KHN values than the dual-cured resin cement (p = 0.00001). LuxaCore-Dual exhibited higher KHN values than FluoroCore2 (p = 0.00001) when they were allowed to self-cure, while no significant differences in KHN values were observed among the light-activated products. The results suggest that dual-cured composite resin core build-up materials may be more reliable than dual-cured resin cements when curing light is not available.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s1806-83242010000200019 | DOI Listing |
Dent Mater J
January 2024
Department of Restorative Dentistry, King Saud University College of Dentistry.
Sci Rep
December 2024
Department of Applied Dental Sciences, Faculty of Applied Medical Science, Jordan University of Science and Technology, Irbid, Jordan.
The aim of this study was to investigate the effect of using different core build-up materials on biaxial flexural strength (BFS) of multilayered strength-gradient zirconia ceramic in comparison to lithium disilicate ceramic. Thirty zirconia discs were fabricated from IPS e.max ZirCAD Prime (Zir), 30 discs from IPS e.
View Article and Find Full Text PDFPolym Chem
December 2024
Polymer Science, Zernike Institute for Advanced Materials, University of Groningen Nijenborgh 4 9747 AG Groningen The Netherlands
Carbohydr Polym
January 2025
Department of Materials and Environmental Chemistry, Stockholm University, Svante Arrheniusväg 16C, Stockholm 106 91, Sweden. Electronic address:
Fiber actuators, particularly valuable in soft robotics and environmental sensing, are at the forefront of "smart" materials and materials innovation. In this realm, torsional and tensile biofiber actuators, notable for their cost-effectiveness and biodegradability, mark a critical gap in the development of next-generation functional systems and devices. To address this gap, this study showcased moisture-responsive fiber actuators made from cellulose nanofibrils (CNFs).
View Article and Find Full Text PDFJ Clin Pediatr Dent
November 2024
Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, 600077 Chennai, India.
Stainless-steel crowns (SSCs) are the most durable restorative option for deciduous teeth, although they are unsightly. However, prefabricated zirconia crowns (ZCs) look more pleasant but require substantial dental preparation. Recently, BioFlx crowns have been introduced as a white-colored alternative to SSCs, providing both flexibility and aesthetics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!