Objective: The aim of this prospective study was to evaluate the concept of intraoral welding as a suitable technique for the placement of a final restoration in the edentulous patient on the same day as surgery.

Method And Materials: Any patient with a completely edentulous arch who was considered eligible received a fixed restoration supported by an intraorally welded titanium bar. Definitive abutments were connected to the implants and then welded to a titanium bar using an intraoral welding unit. This framework was used to support the definitive acrylic restoration, which was fitted on the same day as implant placement. Restoration and implant success, mean marginal bone loss, pocket probing depth, and bleeding on probing were assessed over a 36-month follow-up period.

Results: Twenty-six patients with an edentulous maxilla and 34 patients with an edentulous mandible, with a mean age of 57.1 years (SD = 17.9, n = 60), were consecutively treated with 324 immediately loaded implants. No fractures or radiographically detectable alteration of the welded framework was evident. A total of 321 (99.1%) implants osseointegrated and were clinically stable at the 6-month follow-up. At the 36-month follow-up, the accumulated mean marginal bone loss was, respectively, 0.967 mm (SD = 0.361) for the maxillary cases and 1.016 mm (SD = 0.413) for the mandibular cases.

Conclusions: It is possible on the same day of surgery to successfully rehabilitate the edentulous patient with a fixed definitive prosthesis supported by an intraorally welded titanium framework.

Download full-text PDF

Source

Publication Analysis

Top Keywords

welded titanium
16
edentulous patient
12
intraorally welded
12
titanium framework
8
prospective study
8
intraoral welding
8
supported intraorally
8
titanium bar
8
marginal bone
8
bone loss
8

Similar Publications

Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.

Cureus

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.

View Article and Find Full Text PDF

Ultrasound can improve the quality of finished products by reducing porosity and enhancing microstructure in selective laser melting, directed energy deposition, and laser beam welding. This study evaluates the efficiency of ultrasound produced by a pulsed laser via the optoacoustic effect. A quantitative model of collapse of vapor-gas bubbles has been developed under the conditions of ultrasonic treatment at near resonance frequencies.

View Article and Find Full Text PDF

TC17 titanium alloy is widely used in the aviation industry for dual-performance blades, and linear friction welding (LFW) is a key technology for its manufacturing and repair. However, accurate evaluation of the mechanical properties of TC17-LFW joints and research on their joint fracture behavior are still not clear. Therefore, this paper used the finite element numerical simulation method (FEM) to investigate the mechanical behavior of the TC17-LFW joint with a complex micro-structure during the tensile processing, and predicted its mechanical properties and fracture behavior.

View Article and Find Full Text PDF

Large enhancement of ferroelectric properties of perovskite oxides via nitrogen incorporation.

Sci Adv

January 2025

State Key Laboratory of Advanced Welding and Joining of Materials and Structures, School of Materials Science and Engineering, Harbin Institute of Technology, Shenzhen 518055, China.

Perovskite oxides have a wide variety of physical properties that make them promising candidates for versatile technological applications including nonvolatile memory and logic devices. Chemical tuning of those properties has been achieved, to the greatest extent, by cation-site substitution, while anion substitution is much less explored due to the difficulty in synthesizing high-quality, mixed-anion compounds. Here, nitrogen-incorporated BaTiO thin films have been synthesized by reactive pulsed-laser deposition in a nitrogen growth atmosphere.

View Article and Find Full Text PDF

Resistance spot-welded joints are crucial parts in contemporary manufacturing technology due to their ubiquitous use in the automobile industry. The necessity of improving manufacturing efficiency and quality at an affordable cost requires deep knowledge of the resistance spot welding (RSW) process and the development of artificial neural network (ANN)- and machine learning (ML)-based modelling techniques, apt for providing essential tools for design, planning, and incorporation in the welding process. Tensile shear force and nugget diameter are the most crucial outputs for evaluating the quality of a resistance spot-welded specimen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!