The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) of 18 subjects as the perpendicular distance between the center of the pulley of the humerus to the line through the center of the TB tendon. The moment arm increased as the elbow flexion angle decreased, from 1.74±0.13 cm at 110° to 2.39±0.14 cm at 30°. The maximal anatomical cross-sectional area of the TB muscle was significantly correlated with the moment arms at all joint positions (r=0.545-0.803, p<0.05). Furthermore, the circumference of the upper arm was also significantly correlated with the moment arms at all joint positions, except for 70° (r=0.504-0.702, p<0.05). These results indicate that the moment arm length of the TB muscle is affected by the muscle anatomical cross-sectional area.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2010.06.013 | DOI Listing |
Sci Rep
January 2025
Department of Epidemiology and Biostatistics, Key Laboratory of Molecular Cancer Epidemiology, National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin Medical University, Tianjin, 300060, China.
Positive results from cancer screenings, like a cancer diagnosis, can increase the risk of cardiovascular disease (CVD) mortality due to heightened psychological stress. However, positive screening results may also serve as a teachable moment to encourage the adoption of a healthier lifestyle. Consequently, the overall association between positive screenings and CVD mortality risk remains unclear.
View Article and Find Full Text PDFBioinspir Biomim
January 2025
Southwest University of Science and Technology, No. 59, Middle Section of Qinglong Avenue, Fucheng District, Mianyang City, Sichuan Province, Mianyang, Sichuan, 621010, CHINA.
The Cable-Driven Hyper-redundant Manipulator (CDHM), distinguished by its high flexibility and adjustable stiffness, is extensively utilized in confined and obstacle-rich environments such as aerospace and nuclear facilities. This paper introduces a novel CDHM inspired by the trunk of elephants, which changes the arm structure from cylindrical to conical. This alteration diminishes the arm's self-weight, reduces the moment arm of gravity, decreases the volume of the end joint, narrows the stroke of the driving cables, and boosts the maximum joint speed of the manipulator.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopaedic Surgery, Atrium Health Musculoskeletal Institute, 2001 Vail Ave, Charlotte, NC, USA.
Background: Hip morphology variations, particularly in femoral neck shaft angle (NSA) and iliac wing width (IWW), have been associated with gluteal tendinopathy. However, the biomechanical implications of these morphological differences on gluteal muscle function are not well understood. This study investigates how NSA and IWW influence gluteal muscle forces, moment arms, and estimated tendon loads during walking, aiming to provide insights into the potential biomechanical pathways that may contribute to altered lateral hip loading patterns.
View Article and Find Full Text PDFJ Biomech
January 2025
Faculty of Health and Sports Science, Doshisha University, Kyoto, Japan; Human Performance Laboratory, Waseda University, Saitama, Japan.
A muscle's mechanical action is affected by its architecture. However, less is known about the architecture of muscles with broad attachments: "end-divergent" muscles. Potential regional variation of fascicle orientation in end-divergent muscles suggests that their mechanical action varies by region.
View Article and Find Full Text PDFSports (Basel)
December 2024
Department of Biomedical Engineering and Chemical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA.
Shoulder and elbow injuries are prevalent among baseball players, particularly pitchers, who experience repetitive eccentric loading of the shoulder, leading to muscle damage and increased injury risk. Nearly 40% of shoulder injuries in baseball occur in pitchers, with many facing low rates of return to sport. The rotator cuff (RC) muscles-supraspinatus (SSP), infraspinatus (ISP), subscapularis (SSC), and teres minor (TMin)-are crucial for shoulder stability, movement, and force generation, particularly in overhead sports.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!