A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interlaboratory validation of the in vitro eye irritation tests for cosmetic ingredients (9). Evaluation of cytotoxicity test on HeLa cells. | LitMetric

The cytotoxicity test using MTT on HeLa cells (HeLa-MTT) was evaluated as an alternative method to the Draize eye irritation test (Draize test) by six to eight laboratories. The 50% inhibition concentration (EC(50)) for MTT reduction was calculated. A total of thirty-nine test chemicals were examined. The average interlaboratory coefficient of variation (CV) of the present assay was 25%. Comparison of the in vitro test results with those of the Draize test revealed a correlation coefficient of -0.799 between the log(EC(50)) value and the maximum average total score (MAS) for a 10% solution or suspension. The following characteristics of HeLa-MTT have become apparent through this validation: (1) HeLa-MTT could be applied to all substances including water-insoluble substances, esters, a colour additive, and a substance which is known to directly reduce MTT; (2) there is good interlaboratory reproducibility and strong correlation between HeLa-MTT and Draize MAS; (3) results for strong acids, alkanolamines and alcohols (lower mono-ol) clearly deviate from other samples with respect to the correlation between HeLa-MTT and Draize MAS. These results suggest that HeLa-MTT may be useful for predicting the Draize MAS if definite criteria can be established for applicable compounds.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0887-2333(98)00072-1DOI Listing

Publication Analysis

Top Keywords

draize mas
12
eye irritation
8
cytotoxicity test
8
hela cells
8
test draize
8
draize test
8
correlation hela-mtt
8
hela-mtt draize
8
test
7
hela-mtt
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!