Evaluation of the HET-CAM-TSA method as an alternative to the draize eye irritation test.

Toxicol In Vitro

Department of Genetic and In Vitro Toxicology, Janssen Research Foundation-BEERSE, Belgium.

Published: October 1997

The Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) method was modified in our laboratory by means of microscopic evaluation, a clear description of the three in vitro endpoints (haemorrhage, lysis and coagulation) and the use of a test substance applicator (TSA). A previous study on 46 chemicals demonstrated the usage of the HET-CAM-TSA assay as a screening test for eye irritancy. In order to extend our database and to come to a more reliable conclusion concerning the use of the HET-CAM-TSA method, a second set of 60 test substances was tested. The in vitro irritation scores (IS) were compared with the in vivo modified maximum average scores (MMAS) calculated 24 hr after instillation. The MMAS irritancy threshold was set at 15.0. The results were analysed according to the Cooper's parameters (specificity, sensitivity and concordance with the Draize test) and the Pearson's correlation coefficient. It was concluded that the HET-CAM-TSA test was a valuable screening test. To compensate for the misclassifications generated, it was also concluded that the HET-CAM-TSA method should be considered as a part of a test battery, together with the Bovine Corneal Opacity-Permeability (BCOP) assay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0887-2333(97)00074-xDOI Listing

Publication Analysis

Top Keywords

het-cam-tsa method
12
test
8
screening test
8
concluded het-cam-tsa
8
evaluation het-cam-tsa
4
method
4
method alternative
4
alternative draize
4
draize eye
4
eye irritation
4

Similar Publications

Evaluation of the HET-CAM-TSA method as an alternative to the draize eye irritation test.

Toxicol In Vitro

October 1997

Department of Genetic and In Vitro Toxicology, Janssen Research Foundation-BEERSE, Belgium.

The Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) method was modified in our laboratory by means of microscopic evaluation, a clear description of the three in vitro endpoints (haemorrhage, lysis and coagulation) and the use of a test substance applicator (TSA). A previous study on 46 chemicals demonstrated the usage of the HET-CAM-TSA assay as a screening test for eye irritancy. In order to extend our database and to come to a more reliable conclusion concerning the use of the HET-CAM-TSA method, a second set of 60 test substances was tested.

View Article and Find Full Text PDF

Evaluation of a modified HET-CAM assay as a screening test for eye irritancy.

Toxicol In Vitro

August 1996

Department of In Vitro Toxicology, Janssen Pharmaceutica n.v., Turnhoutseweg 30, B-2340 Beerse, Belgium.

The hen's egg test-chorioallantoic membrane (HET-CAM) assay, an alternative to the Draize eye irritation test, was developed by Luepke and has been improved on by means of a microscopic examination and the use of a test substance applicator (TSA). The TSA is a double teflon ring in which a perlon mesh is locked, and has several advantages over conventional protocols, reducing subjectivity of the method and avoiding the need for rinsing after treatment. It was confirmed by statistical analysis that the HET-CAM-TSA method can reproduce potentialin vivo irritant effects on the conjunctiva.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!