[3D visualization for simulating percutaneous transcatheter closure of atrial septal defect:a pilot clinical study].

Zhonghua Xin Xue Guan Bing Za Zhi

Department of Pediatric Cardiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.

Published: April 2010

Objective: To evaluate the clinical value of 3D visualization method for simulating percutaneous transcatheter closure of atrial septal defect (ASD).

Methods: 3D volume render method was used for visualizing ASD and surrounding structures and 3D modeling method was applied for simulate the shape of occlusion device. The size and the distance between the lower edge of device and atria-ventricular valve of simulation occluder and actual selected atrial septal occluder (ASO) were compared in 30 patients underwent successful transcatheter closure of ASD.

Results: The location, geometry, size, extent of ASDs in children were displayed in 3D visualization. No significant difference was found between simulation occluder and ASO size measured from left atrium [(26.07 +/- 5.32) cm vs. (25.91 +/- 5.32) cm] and right atrium [(22.13 +/- 5.31) cm vs. (22.08 +/- 5.26) cm, all P > 0.05]. The distances from simulation occluder to mitral valves [(5.76 +/- 2.39) cm] and to tricuspid valves [(8.25 +/- 2.40) cm] were similar as ASO to atria-ventricular valves [(5.61 +/- 2.26) cm and (8.02 +/- 2.48) cm, respectively, all P > 0.05].

Conclusions: The simulating percutaneous transcatheter closure of ASD by 3D visualization technique could be a helpful noninvasive approach for ASO selection before the procedure of transcatheter occlusion of ASD.

Download full-text PDF

Source

Publication Analysis

Top Keywords

transcatheter closure
16
simulating percutaneous
12
percutaneous transcatheter
12
atrial septal
12
simulation occluder
12
closure atrial
8
occluder aso
8
+/-
8
+/- 532
8
transcatheter
5

Similar Publications

Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.

Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.

View Article and Find Full Text PDF

Aortic annular rupture is a rare and usually fatal complication of TAVR. We report the case of a sub-annular aortic rupture contained in the right ventricle and percutaneously repaired. The procedure was complicated by new-onset severe tricuspid regurgitation related to tricuspid injury during wire externalization and immediately treated by transcatheter edge-to-edge repair.

View Article and Find Full Text PDF

Background: Achieving hemostasis of large bore venous access sites can be challenging and time consuming. Closure devices have proven to be superior in achieving hemostasis, reducing time to ambulation and improving patient comfort, compared to manual hemostasis techniques after femoral venous and arterial access. The closure of the jugular vein following large bore access has not been investigated in previous studies.

View Article and Find Full Text PDF