A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Right-sided free wall accessory pathway refractory to conventional catheter ablation: lessons from 3-dimensional electroanatomic mapping. | LitMetric

Introduction: the aim of this study was to delineate the electroanatomic substrates of right-sided free wall (RFW) accessory pathways (APs) that were refractory to conventional catheter ablation utilizing 3-dimensional (3-D) mapping.

Methods And Results: eleven patients with RFW APs that failed initial conventional catheter ablation(s) by a mean of 1.9 ± 0.5 attempts were enrolled in the study. Electroanatomic mapping of the right atrium was performed during orthodromic reciprocating tachycardia in 3 patients and right ventricular pacing in 8 patients. The earliest atrial activation site, which represented the atrial insertion of the AP, was separated from the tricuspid annulus by an average of 14.3 ± 3.9 mm, and the local activation time was 27.8 ± 17.0 ms earlier than that of the corresponding annular point. One patient exhibited an AP with wide branching on the atrial side. RF ablation with an irrigated catheter successfully interrupted AP conduction in all patients without complications.

Conclusions: RFW APs resistant to conventional catheter ablation might be due to unique anatomic AP features such as more epicardial course at the annulus level with atrial insertion distant from the tricuspid annulus. Electroanatomic mapping is helpful to accurately localize the atrial insertion sites of these APs and facilitates catheter ablation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2010.01857.xDOI Listing

Publication Analysis

Top Keywords

conventional catheter
16
catheter ablation
16
electroanatomic mapping
12
atrial insertion
12
right-sided free
8
free wall
8
refractory conventional
8
rfw aps
8
tricuspid annulus
8
catheter
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!