Efficient sensing of nitrite by Fe(bpy)3(2+) immobilized Nafion modified electrodes.

Chem Commun (Camb)

Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi-221 005, India.

Published: September 2010

Fe(bpy)(3)(2+) (where bpy = 2,2' bipyridyl) immobilized Nafion (Nf) modified glassy carbon electrodes were prepared and they showed excellent electrocatalytic oxidation of nitrite (NO(2)(-)) which leads to the sensitive determination of NO(2)(-). Electrostatic repulsion between NO(2)(-) and Nf film is greatly decreased when Nf film is fully exchanged with cations.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c0cc00852dDOI Listing

Publication Analysis

Top Keywords

immobilized nafion
8
nafion modified
8
efficient sensing
4
sensing nitrite
4
nitrite febpy32+
4
febpy32+ immobilized
4
modified electrodes
4
electrodes febpy32+
4
febpy32+ bpy
4
bpy 22'
4

Similar Publications

Aptamer-antibody sandwich immunosensor for electrochemical detection of FT4.

Mikrochim Acta

January 2025

College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, 26 Yuxiang Road, Shijiazhuang, 050018, P. R. China.

An aptamer-antibody sandwich electrochemical immunosensor was studied. FeO/MWCNTs-COOH/Nafion was modified and fixed on a glassy carbon electrode to amplify electrical signals. The antibody was coupled with AuNPs to form conjugates.

View Article and Find Full Text PDF

In this study, a Cu@Ag core-shell was synthesized using a co-precipitation method. To create a new electrochemical sensor, a Cu@Ag core-shell with conductive polymers such as polyalizarin yellow R (PA) and Nafion (Nf) was immobilized on the surface of a glassy carbon electrode (Cu@Ag-Nf/PA/GCE). X-ray diffraction analysis (XRD), energy dispersive X-ray analysis (EDX), transmission electron microscopy (TEM), and Fourier Transform Infrared Spectroscopy (FTIR) techniques were employed to characterize the Cu@Ag-Nf/PA/GCE.

View Article and Find Full Text PDF

It is of great significance to develop sensors for trace pesticide residues detection in food. Herein, an electrochemiluminescence (ECL) sensor with high sensitivity for the detection of methyl parathion (MP) was constructed by combining of the acetylcholinesterase (AChE) enzyme-inhibited reaction with tris-2,2'-bipyridyl ruthenium Ru(bpy) -triethylamine (TEA) system for the first time. A new ECL probe of MIL-100 loaded with Ru(bpy) (Ru-MIL-100) was synthesized, and then Ru-MIL-100 and AChE were immobilized on the electrode with Nafion.

View Article and Find Full Text PDF

ZnO-Nafion assisted optical fiber dual-SPR biosensor for simultaneous detection of urea and uric acid concentrations.

Biosens Bioelectron

March 2025

College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China.

A novel dual-parameter optical fiber biosensor based on surface plasmon resonance (SPR) for simultaneous measurement of urea and uric acid concentrations is proposed in this paper. Based on the principle of positive and negative electric combination, ZnO nanoparticles is selected as the matrix for immobilizing urease and uricase with selective recognition ability, which can also be used as a sensitizing material to increase the refractive index detection sensitivity of SPR by 22%. Then, Nafion ion exchange membrane was introduced to wrap the urea sensing area to avoid crosstalk caused by the overlap of adjacent sensing areas.

View Article and Find Full Text PDF
Article Synopsis
  • * The study compared these electrodes to traditional Ag/AgCl reference electrodes, finding that while Ag/AgCl showed greater charge transfer resistance, the carbon/graphene electrodes maintained comparable sensitivity and performance when lactate oxidase was used in the setup.
  • * Future investigations are necessary to address the reduction in electric current observed with human plasma, indicating potential issues with analyte detection sensitivity due to biological interferents.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!