Microneedles can enhance the penetration of vaccines into the skin for transcutaneous vaccination. In this study for the first time the influence of microneedle geometry on the transport through the formed conduits was visualised in human volunteers by confocal laser scanning microscopy. Three differently shaped 300 μm long microneedle arrays were selected and fluorescein was applied either before or after piercing. Based on the intensity a distinction was made between regions with high and low intensity fluorescence (HIF and LIF). The areas of both intensities were quantified over time. In most cases HIF areas were only present in the stratum corneum, while LIF areas were also present in the viable epidermis. The areas were larger if fluorescein was applied after piercing compared to before piercing. After 15 min almost no HIF was present anymore at the skin surface. The microneedle geometry, but not the manner of application affected the shape and depth of the conduits. In conclusion we showed that the different microneedle arrays are able to form conduits in the skin, but the geometry of the microneedles influences the penetration of the fluorescent dye. This is the first step towards a more rational design of microneedle arrays for transcutaneous vaccination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jconrel.2010.07.104 | DOI Listing |
Acta Biomater
December 2024
UCD Centre for Biomedical Engineering, University College Dublin, Belfield, Dublin 4, Ireland; School of Mechanical & Materials Engineering, University College Dublin, Belfield, Dublin 4, Ireland; UCD Charles Institute of Dermatology, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland; The Conway Institute of Biomolecular and Biomedical Research, University College Dublin, Dublin, Ireland. Electronic address:
Microneedle patches (MNs) hold enormous potential to facilitate the minimally-invasive delivery of drugs and vaccines transdermally. However, the micro-mechanics of skin deformation significantly influence the permeation of therapeutics through the skin. Previous studies often fail to appreciate the complexities in microneedle-skin mechanical interactions.
View Article and Find Full Text PDFInt J Pharm
December 2024
Heinrich Heine University Duesseldorf, Faculty of Mathematics and Natural Sciences, Institute of Pharmaceutics and Biopharmaceutics, Universitätsstraße 1, Duesseldorf 40225, Germany. Electronic address:
Transdermal drug delivery using microneedle array patches has been investigated using a wide range of drug substances. Inkjet printing and micromolding are established methods for the production of microneedle array patches and both were used to combine lisinopril embedded in povidone and ibuprofen in Eudragit® RS / RL in a single patch. Dissolution studies, visual inspection, mechanical strength and insertion into an artificial skin membrane model were investigated.
View Article and Find Full Text PDFBiosens Bioelectron
December 2024
Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; Innovation Platform of Micro/Nano Technology for Biosensing, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311215, PR China. Electronic address:
Plant electrical signals serve as a medium for long-distance signal transmission and are intricately linked to plant stress responses. High-fidelity acquisition and analysis of plant electrophysiological signals contribute to early stress identification, thereby enhancing agricultural production efficiency. While traditional plant electrophysiology monitoring methods like gel electrodes can capture electrical signals on plant surfaces, which face limitations due to the plant cuticle barrier, impacting signal accuracy.
View Article and Find Full Text PDFAnal Chem
December 2024
School of Science, Harbin Institute of Technology, Shenzhen 518055, China.
Oxygen saturation is a crucial indicator in the management of various diseases and in preoperative diagnosis, and the detection of oxygen content is valuable in guiding clinical treatment. However, as the classical and dominant oxygen detection strategies, current photoelectric oximeters and electrochemical-based blood gas analyzers often suffer from significant interindividual variation and poor compliance, respectively. In recent years, wearable microneedles (MNs) for analyzing biomarkers in interstitial fluid (ISF) have received great attention and recognition mainly for the reason that the content of the substances distributed in ISF has a better correlation with that in blood circulation compared with other body fluids such as sweat and saliva.
View Article and Find Full Text PDFAnal Chem
December 2024
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain.
Chronic wound management requires continuous monitoring to assess healing and guide treatment. We developed a hollow microneedle array patch integrated with a lateral flow immunoassay strip to address the need for convenient, home-based diagnostics. This device extracts wound exudate directly from the wound matrix, overcoming the limitations of conventional swab sampling, which relies on surface exudate collection.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!