Introduction: Contemporary cryoablation technology utilizes the Joule-Thomson effect, defined as a change in temperature that results from expansion of a nonideal gas through an orifice or other restriction. We evaluated the effect of initial gas tank pressures on freezing dynamics in a single-probe model and in a multiprobe model using contemporary cryoablation technology.

Materials And Methods: Cryoablation trials were performed in a standardized system of transparent gelatin molds at 25°C. Two sets of trials were performed. The first trial evaluated temperature and ice ball size for a given tank pressure when a single needle was deployed. The second trial recorded ice ball temperatures for each probe when multiple probes were fired simultaneously.

Results: Trial 1: The rate of temperature change is directly related to the initial pressure of the gas being released, and the group with the highest starting pressures reached the lowest mean temperature and had the largest mean ice ball size (p < 0.01). Trail 2: Multiple-probe ablation did not affect the rate of temperature change or final temperature compared with firing a single probe (p > 0.7).

Conclusions: In accordance with the Joule-Thomson effect, higher initial gas pressures used for cryoablation in a transparent gel model demonstrate statistically significant lower temperatures, faster decreases in temperature, and formation of larger ice balls than lower gas pressures do. With contemporary technology, multiple simultaneous cryoprobe deployment does not compromise individual probe efficacy. The use of higher initial tank pressures will theoretically help future cryoprobes be more effective, creating a greater volume of cell necrosis and a smaller indeterminate zone.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2009.0587DOI Listing

Publication Analysis

Top Keywords

ice ball
16
ball size
12
contemporary cryoablation
8
initial gas
8
tank pressures
8
trials performed
8
rate temperature
8
temperature change
8
higher initial
8
gas pressures
8

Similar Publications

Ice cream is popular but contains high amounts of saturated fats and few health-promoting ingredients. In the presence of xanthan gum (0.25%), blueberry peel particles prepared through ball-milling treatment (BMPs) were used to prepare ice cream containing camellia oil as a fat replacer.

View Article and Find Full Text PDF

Recent experiments revealed a new amorphous ice phase, medium-density amorphous ice (MDA), formed by ball-milling ice at 77 K [Rosu-Finsen , Science , 474-478 (2023)]. MDA has density between that of low-density amorphous (LDA) and high-density amorphous (HDA) ices, adding to the complexity of water's phase diagram, known for its glass polyamorphism and two-state thermodynamics. The nature of MDA and its relation to other amorphous ices and liquid water remain unsolved.

View Article and Find Full Text PDF

Ball milling treatment could affect the microstructures, improve the emulsification properties of curdlan (CL) and regulate the emulsion gel properties of CL based emulsion gel in two-ways. With increasing ball milling time (1 h-8 h), the particle size first decreased and then increased, the relative crystallinity decreased, and the contact angle increased. Ball milled curdlan (BMCL)-6 h showed the best emulsifying property and stability, which was the combined effects of decreased particle size and increased hydrophobic property.

View Article and Find Full Text PDF

Including the Hollow Viscera (Stomach or Bowel) within the Ice Ball during Cryoablation: A Review of Adverse Events.

J Vasc Interv Radiol

October 2024

Division of Vascular and Interventional Radiology, Department of Medical Imaging, University of Arizona, Tucson, Arizona.

Purpose: To evaluate the safety of including hollow viscus (stomach or bowel) in the ice ball during cryoablation.

Materials And Methods: Forty-three patients who underwent 50 cryoablations between January 1, 2012, and February 1, 2023, were retrospectively reviewed and compared with a control cohort of those who underwent cryoablation without hollow visceral involvement (n = 86). Adverse events (AEs) were stratified by the Society of Interventional Radiology (SIR) AE classification system, 2017.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!