Diffraction effects in optical microelectromechanical system Michelson interferometers.

Appl Opt

Biomedical Engineering Department, Faculty of Engineering, Helwan University, 1 Sherif Street, Helwan, Helwan, Egypt.

Published: July 2010

We study the effect of diffraction on the performance of microelectromechanical system Michelson interferometers. By using a simple Gaussian model, we calculate the degradation of the interferometer visibility due to the diffraction effect. We then use this model to estimate the optimum detector diameter to maximize the fringe visibility at the interferometer output and study its effect on the resolution of Fourier transform spectrometers based on Michelson interferometers.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.49.003960DOI Listing

Publication Analysis

Top Keywords

michelson interferometers
12
microelectromechanical system
8
system michelson
8
diffraction effects
4
effects optical
4
optical microelectromechanical
4
interferometers study
4
study diffraction
4
diffraction performance
4
performance microelectromechanical
4

Similar Publications

In this Letter, we present a fiber-optic radio frequency (RF) transmission scheme based on phase modulation with an interferometric detection structure. A self-developed Michelson interferometer (MI) is used to demodulate the frequency signal via an electrically controlled optical shifter. The two complementary outputs from the interferometer are detected using a balanced detector, which suppresses the common-mode noise of the fiber link.

View Article and Find Full Text PDF

High-Performance Telescope System Design for Space-Based Gravitational Waves Detection.

Sensors (Basel)

November 2024

MOE Key Laboratory of Fundamental Physical Quantities Measurement and Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China.

Article Synopsis
  • Space-based gravitational wave (GW) detection utilizes the Michelson interferometry principle to create long baseline laser interferometers capable of sensing signals within a frequency range of 10-1 Hz.
  • The paper introduces an advanced design using an off-axis four-mirror configuration that minimizes wavefront aberration and enhances stray light suppression, addressing background noise issues.
  • This improved design achieves a wavefront error of less than λ/500 in the main field of view and can reach an error of less than λ/30 with a 92% probability, making it a strong candidate for future GW detection projects.
View Article and Find Full Text PDF

Atmospheric temperature information in the near space is of great academic significance and engineering value to support the development and utilization of the near space. Based on the theory of O molecular dayglow spectroscopy and the mechanism of atmospheric radiative transfer, a method is proposed for the joint retrieval of temperature profiles in the near space using O(aΔ) and O(b∑ ) bands dayglow spectroscopy signal with the self-absorption effect. First, the temperature dependence of O(aΔ) and O(b∑ ) bands dayglow is investigated, and the influence of the self-absorption effect on the radiative transfer characteristics is analyzed in the limb-view mode.

View Article and Find Full Text PDF

We present a low-resource and robust optical implementation of the four-dimensional Grover coin, a four-port linear-optical scatterer that augments the low dimensionality of a regular beam-splitter. While prior realizations of the Grover coin required a potentially unstable ring cavity to be formed, this version of the scatterer does not exhibit any internal interference. When this Grover coin is placed in another system, it can be used for interferometry with a higher-dimensional set of optical field modes.

View Article and Find Full Text PDF

Significance: Optical coherence tomography (OCT) images are prone to image artifacts due to the birefringence of the sample or the optical system when a polarized light source is used for imaging. These artifacts can lead to degraded image quality and diagnostic information.

Aim: We aim to mitigate these birefringence-related artifacts in OCT images by adding a depolarizer module in the reference arm of the interferometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!