A protein separation technology using the microfluidic device was developed for the more rapid and effective analysis of target protein. This microfluidic separation system was carried out using the aqueous two-phase system (ATPS) and the ionic liquid two-phase system (ILTPS) for purification method of the protein sample, and the three-flow desalting system was used for the removal of salts from the sucrose-rich sample. Partitioning of the protein sample was observed in ATPS or ILTPS with the various pHs. The microdialysis system was applied to remove small molecules, such as sucrose and salts in the microfluidic channel with the different flow rates of buffer phase. A complex purification method, which combines microdialysis and ATPS or ILTPS, was carried out for the effective purification of bacteriorhodopsin (BR) from the purple membrane of Halobacterium salinarium, which was then analyzed by sodium dodecyl sulfatepolyacrylamide gel electrophoresis and matrix-assisted laser desorptionionization time-of-flight. Furthermore, we were able to make a stable three-phase flow controlling the flow rate in the microfluidic channel. Our complex purification methods were successful in purifying and recovering the BR to its required value.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2905269 | PMC |
http://dx.doi.org/10.1063/1.3298608 | DOI Listing |
Int J Nanomedicine
January 2025
School of Pharmacy, Changzhou University, Changzhou, People's Republic of China.
Introduction: Osteoarthritis (OA) is a degenerative joint disease characterized by articular cartilage degeneration. Chondrocyte inflammation, apoptosis, and extracellular matrix degradation accelerated OA progression. MicroRNA (miRNA) has the potential to be a therapeutic method for osteoarthritis.
View Article and Find Full Text PDFACS Omega
January 2025
Chair of Analytical Chemistry, Institute of Chemistry, University of Tartu, Ravila 14a, 50411Tartu, Estonia.
Water is an essential part of everyday life, and similarly, numerous industries depend on it. Regular water analysis is needed for both home use and in more specific fields, e.g.
View Article and Find Full Text PDFACS Omega
January 2025
Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, United States.
The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions.
View Article and Find Full Text PDFTalanta
January 2025
Medical School of Tianjin University, Academy of Medical Engineering and Translational Medicine, Tianjin, 300072, China. Electronic address:
Atherosclerosis-induced cardiovascular diseases are a leading cause of disability and mortality worldwide. Currently, clinical diagnosis of atherosclerosis relies on analysis and assessment by large medical equipment and specialized professionals, involving invasive testing, which limits early detection and prognosis of atherosclerosis. Herein, this work develops a flexible wearable ring sensor for non-invasive real-time in situ monitoring of biomarkers associated with atherosclerosis.
View Article and Find Full Text PDFAnal Biochem
January 2025
Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah, Iran.
H5N1 flu is a highly virulent and variable subtype of influenza with significant epidemic and pandemic potential. In this study, we introduce a novel, maskless, and rapid manufacturing process for a microfluidic chip integrated with electrodes for the quantitative detection of H5N1-DNA sequences. This detection leverages a catalytic redox-recycling signal via a novel Fe₃O₄@TMU-8 nanocomposite, which facilitates the turnover of the oxidation state of [Ru(NH₃)₆]³⁺, thereby amplifying the electrochemical signal output.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!