Background: Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits.
Methods And Results: From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (>or=1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8+/-4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5+/-2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction.
Conclusions: In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4240270 | PMC |
http://dx.doi.org/10.1161/CIRCULATIONAHA.109.921692 | DOI Listing |
Am Heart J
January 2025
Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN 55905. Electronic address:
Background: Patients with congenital heart disease (CHD) often require prosthetic valve implantation, increasing their lifetime risk of developing prosthetic valve endocarditis (PVE). The purpose of this study was to determine the incidence, risk factors, and outcomes of PVE in adults with CHD.
Method: Retrospective cohort study of adults with CHD and prior prosthetic valve implantation (2003-2023).
Ann Thorac Surg Short Rep
September 2024
Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center and Children's Medical Center, Dallas, Texas.
Background: In small children with left atrioventricular valve dysfunction, valve repair is preferred but some will require valve replacement. No prosthetic valve has growth potential, bioprostheses have poor durability, and mechanical prostheses have high rates of thromboembolic and hemorrhagic complications. We reviewed our experience with a modified bovine jugular vein valve designed for use in the right ventricular outflow tract (Melody valve, Medtronic) and compared this with contemporary mechanical valve replacement.
View Article and Find Full Text PDFInt J Cardiol Congenit Heart Dis
December 2024
Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Objectives: To describe the workflow and value of three-dimensional rotational angiography (3DRA) in percutaneous pulmonary valve implantation (PPVI).
Background: 3DRA offers visualization of the entire topography in the chest and may enhance safety and reduce the risk for complications in PPVI through improved pre-procedural planning and per-procedural guidance.
Methods: All PPVI procedures with the use of 3DRA performed between August 2011 and December 2022 were reviewed.
Catheter Cardiovasc Interv
December 2024
Centre de Référence Malformations Cardiaques Congénitales Complexes-M3C, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris, Paris, France.
Background: Infective endocarditis (IE) poses significant risks following percutaneous pulmonary valve implantation (PPVI) or surgical replacement (PVR).
Aims: This study evaluates the effectiveness of emergency percutaneous treatment in stabilizing patients with severe right ventricular dysfunction or obstructive cardiac shock, allowing for delayed surgical or percutaneous valve replacement.
Methods: This retrospective study examines 16 patients (age 19.
Langmuir
December 2024
Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.
Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.