A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preload loss and bacterial penetration on different implant-abutment connection systems. | LitMetric

AI Article Synopsis

  • Preload loss can lead to issues like implant-abutment misfit and increased risk of implant failure due to bacterial colonization.
  • The study evaluated four implant-abutment connection systems under thermal cycling and mechanical fatigue, assessing how these factors affect preload and bacterial penetration.
  • Findings indicated that while preload loss varied significantly across systems, there was no direct relationship between preload loss and bacterial penetration at the implant-abutment interface.

Article Abstract

Preload loss can favor the occurrence of implant-abutment interface misfit, and bacterial colonization at this interface may lead to implant failure. The aim of this study was to evaluate the preload loss and bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems subjected to thermal cycling and mechanical fatigue (TM). Four different implant-abutment connection systems were evaluated (n=6): external hexagon with universal post, Morse taper with universal post, Morse taper with universal post through bolt, and locking taper with standard abutment. The assemblies (implant-abutment) were subjected to a thermal cycling regimen (1,000 cycles of 5 degrees C and 55 degrees C) and to mechanical fatigue (1.0 million cycles, 1.0 Hz, 120 N). The assemblies were immersed in Tryptic Soy + Yeast Extract broth containing Streptococcus sanguinis and incubated at 37 degrees C and 10% CO(2) for 72 h. Detorque values were recorded. The bacterial penetration was assessed and the abutments were observed by scanning electron microscopy. The preload data were analyzed statistically by two-way ANOVA and Tukey's test at 5% significance level. All screw abutment systems showed significantly higher (p<0.05) detorque values when subjected to TM and all conical systems presented bacterial penetration. The results show no relationship between the preload loss and the bacterial penetration.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402010000200006DOI Listing

Publication Analysis

Top Keywords

preload loss
12
bacterial penetration
12
connection systems
12
universal post
12
loss bacterial
8
penetration implant-abutment
8
implant-abutment connection
8
implant-abutment interface
8
external hexagon
8
subjected thermal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!