Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Diffusion tensor imaging (DTI) offers the promise of improved tumor localization in prostate cancer but the technique suffers from susceptibility-induced artifacts that limit the achievable resolution. The present work employs a reduced field-of-view technique that enables high-resolution DTI of the prostate at 3T. Feasibility of the approach is demonstrated in a clinical study including 26 patients and 14 controls.
Materials And Methods: Reduced field-of-view acquisition was established by non-coplanar application of the excitation and the refocusing pulse in conjunction with outer volume suppression. Accuracy for cancer detection of apparent diffusion coefficient (ADC) mapping and T2-weighted imaging was calculated and compared with reference to the findings of trans-rectal ultrasound-guided octant biopsy. Mean ADCs and fractional anisotropy (FA) values in the patients with positive and negative biopsies were compared to each other and to the controls.
Results: Fine anatomical details were successfully depicted on the ADC maps with sub-millimeter resolution. Accuracy for prostate cancer detection was 73.5% for ADC maps and 71% for T2-weighted images, respectively. Cohen's kappa (κ=0.48) indicated moderate agreement of the two methods. The mean ADCs were significantly lower, the FA values higher, in the patients with positive biopsy than in the patients with negative biopsy and the controls. Monte Carlo simulations showed that the FA values, but not the ADCs, were slightly overestimated. Bootstrap analysis revealed that the ADC, but not the FA value, is a highly repeatable marker.
Conclusion: In conclusion, the present work introduces a new approach for high-resolution DTI of the prostate enabling a more accurate detection of focal tumors especially useful in screening populations or as a potential navigator for image-guided biopsy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejrad.2010.06.038 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!