Background: Trocar placement presently is mostly empiric. Our goal was to define simple distances from bony landmarks to locate the optimal ergonomic placement of manipulation trocars for access to the lower esophagus and hiatal orifice, for suture placement, and knotting of the gastric fundus and crura. Hypothesizing that the ideal ergonomic principles of a manipulation angle of 60°, an elevation angle (α(e)) of 30° to 60°, and an intracorporeal/extracorporeal length ratio (I/E) of working instruments close to 1:1 are interrelated by simple trigonometric functions, the variations of each of these parameters were calculated in a dependent manner for 2 standard lengths of needle holders: 48.5 cm and 58.5 cm.
Results: Trocar placement can be calculated easily according to simple formulas dependent on the α(e), the distance from the sternoxiphoid junction to the median of the intertrocar span (d) and the vertical distance from the stenoxiphoid junction to the average distance between the apex of the hiatal orifice and the anterior aspect of the esophagus (XH'): when the α(e) is 30°: d is XH' √2 and when α(e) is 45°, d is XH'/√2. Likewise, when α(e) is 30° the intertrocar span (LR) is 2XH', half on either side of the optical axis (d), and when α(e) is 45°, LR is XH' √2, XH'/√2 on either side of the optical axis. The most ergonomic solution is to work with an α(e) of 40° to 45° by placing the 2 working (manipulation) trocars, between 10 and 14 cm caudad from the sternoxiphoid junction, between 10 and 12 cm on either side of the longitudinal axis corresponding to the optic-target axis. The shorter needle holder works best in this configuration because the I/E ratio will be between .8 and 1. If, however, the surgeon wants to work with an α(e) closer to 30°, then the longer needle holder should be used, and the trocars should be placed between 20 and 21 cm from the sternoxiphoid junction, 14.5 to 15 cm on either side of the optical axis. The I/E ratio will vary between 1 and 1.1. When a 1/1 I/E ratio was prioritized, the α(e) would be 40° and 32°, for the shorter and longer instruments, respectively. The deeper crural closure requires increasing the α(e) by 2° and 3°, respectively. Hyperlordosis, as obtained by placing a cushion under the patient's back, shortens the distances, allowing placement of the trocars closer to the sternoxiphoid junction.
Conclusions: Based on ergonomic principles (manipulation angle, 60°; α(e), 40°-45°; and an I/E ratio of working instruments, close to 1:1), simple trigonometric considerations allow easy calculation of the ideal placement of trocars corresponding to working instruments in hiatal surgery necessary for ergonomic dissection, suturing, and intracorporeal knotting. Ideal trocar placement is dependent only on the vertical depth of the target organ.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjsurg.2010.01.029 | DOI Listing |
Cancers (Basel)
December 2024
Department of Maternal Infant and Urologic Sciences, "Sapienza" University of Rome, 00185 Rome, Italy.
: Robot-assisted radical prostatectomy (RARP) for the treatment of prostate cancer (PCa) has been standardized over the last 20 years. At our institution, only n = 3 rob arms are used for RARP. In addition, n = 2, 12 mm lap trocars are placed for the bedside assistant symmetrically at the midclavicular lines, which allows for direct pelvic triangulation and greater involvement of the assisting surgeon.
View Article and Find Full Text PDFThorac Cardiovasc Surg
January 2025
Thoracic Surgery, Halic Universitesi, Beyoglu, Turkey.
Background: Segmentectomy operation became a preferable operation for small lesions due to the importance of saving lung parenchyma. Using robotic technology has too many advantages for segmentectomy operations. Websites such as YouTube have become educational tools for surgical trainees.
View Article and Find Full Text PDFRetina
June 2024
Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.
Purpose: Current treatments for retinoblastoma facilitate globe salvage but can result in vitreoretinal disorders that may require surgery. There is controversy on surgical approaches in eyes with retinoblastoma. Here we describe a transcorneal vitrectomy approach that avoids the use of chemotherapy or cryotherapy.
View Article and Find Full Text PDFJBJS Essent Surg Tech
January 2025
Department of Orthopaedic Surgery, Montefiore Medical Center, Bronx, New York.
Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.
Description: The procedure can be completed in a standard operating theater without the need for special instruments.
Neurospine
December 2024
Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
This video provides a step-by-step guide for performing the hybrid endoscopic thoracic discectomy using navigation and robotic arm for addressing high migrated calcified disc herniation. With the development of techniques, endoscopic spine surgery has emerged as a reliable treatment for thoracic myelopathy. This approach offers high-resolution, off-axis visualization of the surgical field.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!