[Functional results with two multifocal intraocular lenses with different near addition].

Ophthalmologe

Augenklinik des Knappschaftskrankenhauses, An der Klinik 10, 66280 Sulzbach, Deutschland.

Published: February 2011

Background: The reduction of the near addition of multifocal intraocular lenses from +4 D to +3 D should improve the visual function in the intermediate distance. The ReSTOR +3 D is a multifocal lens with a near addition of 3 D.

Patients And Methods: In a prospective study the new ReSTOR +3 D was compared to the former ReSTOR platform with 4 D near addition. A total of 40 patients received 1 of these 2 multifocal lenses bilaterally in both eyes after uneventful phacoemulsification in otherwise sound cataract eyes (20 patients ReSTOR +3 D, 20 patients ReSTOR + 4D). After 3 months the following parameters were assessed: uncorrected and corrected distance visual acuity, near vision at different distances, contrast sensitivity, defocus curve and anterior and posterior segments. The functional tests were performed monocularly and binocularly.

Results: Uncorrected binocular distance visual acuity (decimal) was 0.93 (logMAR 0.03 ± 0.12) in the ReSTOR +3 D group and 1.05 (-0.02 ± 0.1) in the ReSTOR +4 D group. In the intermediate distance the ReSTOR +3 D performed slightly better at 40 cm (0.68 versus 0.56) (logMAR 0.17 ± 0.14 versus 0.24 ± 0.18). The difference was significant (p<0.01) at 70 cm (0.69 versus 0.43) (logMAR 0.16 ± 0.27 vs 0.37 ± 0.2). The superior performance of the ReSTOR +3 D in the intermediate distance was also clearly visible in the defocus curves. All functional tests revealed significantly better results when performed binocularly.

Conclusion: The ReSTOR +3 D multifocal intraocular lens performed significantly better in the intermediate distance compared to the ReSTOR +4 D. The other functional tests showed excellent and equal results with both lenses. The reduction of near addition does not increase dysphotopsia, particularly halos. Complaints of unsatisfactory vision in the intermediate distance were reported only by patients with the ReSTOR +4 D. The new ReSTOR +3 D is likely to improve the acceptance of multifocal intraocular lenses.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00347-010-2220-xDOI Listing

Publication Analysis

Top Keywords

multifocal intraocular
8
intraocular lenses
8
intermediate distance
8
restor
8
distance restor
8
patients restor
8
distance visual
8
visual acuity
8
restor group
8
[functional multifocal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!