A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Protected carotid stenting in high-risk patients: results of the SpideRX arm of the carotid revascularization with ev3 arterial technology evolution trial. | LitMetric

Purpose: A prospective nonrandomized multicenter registry of 160 patients with severe carotid stenosis and high-risk features for carotid endarterectomy was conducted during the 3-month period from March to May 2005.

Methods: Carotid artery stenting (CAS) was performed with the SpideRX™ Embolic Protection System (ev3, Inc., Plymouth, MN, USA) as part of an investigational device exemption from the Food and Drug Administration.

Results: The primary end-point of major adverse cardiac and cerebrovascular events at 30 days after CAS was observed in nine patients (5.6%), including death in four patients (2.5%), nonfatal stroke in five patients (3.1%), and nonfatal myocardial infarction in one patient (0.6%). A secondary end-point of technical success (defined as successful deployment of all devices, filter retrieval, and final diameter stenosis <50%) was achieved in 156 of 160 patients (97.5%). The only independent predictor of death or stroke at 30 days was baseline stenosis severity (P < 0.05).

Conclusion: CAS with distal embolic protection using the SpideRX™ Embolic Protection System is a reasonable alternative for revascularization of some high-risk patients with severe carotid stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8183.2010.00578.xDOI Listing

Publication Analysis

Top Keywords

patients
5
protected carotid
4
carotid stenting
4
stenting high-risk
4
high-risk patients
4
patients spiderx
4
spiderx arm
4
carotid
4
arm carotid
4
carotid revascularization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!