A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

highly selective amino acid salt solutions as absorption liquid for CO(2) capture in gas-liquid membrane contactors. | LitMetric

The strong anthropogenic increase in the emission of CO(2) and the related environmental impact force the developments towards sustainability and carbon capture and storage (CCS). In the present work, we combine the high product yields and selectivities of CO(2) absorption processes with the advantages of membrane technology in a membrane contactor for the separation of CO(2) from CH(4) using amino acid salt solutions as competitive absorption liquid to alkanol amine solutions. Amino acids, such as sarcosine, have the same functionality as alkanol amines (e.g., monoethanolamine=MEA), but in contrast, they exhibit a better oxidative stability and resistance to degradation. In addition, they can be made nonvolatile by adding a salt functionality, which significantly reduces the liquid loss due to evaporation at elevated temperatures in the desorber. Membrane contactor experiments using CO(2)/CH(4) feed mixtures to evaluate the overall process performance, including a full absorption/desorption cycle show that even without a temperature difference between absorber and desorber, a CO(2)/CH(4) selectivity of over 70 can be easily achieved with the sarcosine salt solution as absorption liquid. This selectivity reaches values of 120 at a temperature difference between absorber and desorber of 35 degrees C, compared to a value of only 60 for MEA under the same conditions. Although CO(2) permeance values are somewhat lower than the values obtained for MEA, the results clearly show the potential of amino acid salt solutions as competitive absorption liquids for the energy efficient removal of CO(2). In addition, due to the low absorption of CH(4) in sarcosine compared to MEA, the loss of CH(4) is reduced and significantly higher CH(4) product yields can be obtained.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cssc.201000076DOI Listing

Publication Analysis

Top Keywords

amino acid
12
acid salt
12
salt solutions
12
absorption liquid
12
product yields
8
membrane contactor
8
solutions competitive
8
competitive absorption
8
temperature difference
8
difference absorber
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!