Aim: The main aim of this review was to compare the safety and efficacy of the Da Vinci Surgical System (DVSS) and conventional laparoscopic surgery (CLS) in different types of abdominal intervention.
Summary Of Background Data: DVSS is an emerging laparoscopic technology. The surgeon directs the robotic arms of the system through a console by means of hand controls and pedals, making use of a stereoscopic viewing system. DVSS is currently being used in general, urological, gynecologic, and cardiothoracic surgery.
Methods: This systematic review analyses the best scientific evidence available regarding the safety and efficacy of DVSS in abdominal surgery. The results found were subjected to meta-analysis whenever possible.
Results: Thirty-one studies, 6 of them randomized control trials, involving 2166 patients that compared DVSS and CLS were examined. The procedures undertaken were fundoplication (9 studies, one also examining cholecystectomy), Heller myotomy (3 studies), gastric bypass (4), gastrectomy (2), bariatric surgery (1), cholecystectomy (4), splenectomy (1), colorectal resection (7), and rectopexy (1). DVSS was found to be associated with fewer Heller myotomy-related perforations, a more rapid intestinal recovery time after gastrectomy-and therefore a shorter hospital stay, a shorter hospital stay following cholecystectomy (although the duration of surgery was longer), longer colorectal resection surgery times, and a larger number of conversions to open surgery during gastric bypass.
Conclusions: The publications reviewed revealed DVSS to offer certain advantages with respect to Heller myotomy, gastrectomy, and cholecystectomy. However, these results should be interpreted with caution until randomized clinical trials are performed and, with respect to oncologic indications, studies include variables such as survival.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SLA.0b013e3181e6239e | DOI Listing |
Eye (Lond)
January 2025
Bayer Consumer Care AG, Basel, Switzerland.
Comput Methods Programs Biomed
December 2024
Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, Milano, MI, 20133, Italy. Electronic address:
Background And Objective: Helmet-Continuous Positive Airway Pressure (H-CPAP) is a non-invasive respiratory support that is used for the treatment of Acute Respiratory Distress Syndrome (ARDS), a severe medical condition diagnosed when symptoms like profound hypoxemia, pulmonary opacities on radiography, or unexplained respiratory failure are present. It can be classified as mild, moderate or severe. H-CPAP therapy is recommended as the initial treatment approach for mild ARDS.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Department of Biomedical Engineering, Seoul National University College of Medicine, 103 Daehak-ro, Jongno- gu, Seoul, 03080 Republic of Korea.
Unlabelled: With the advent of robot-assisted surgery, user-friendly technologies have been applied to the da Vinci surgical system (dVSS), and their efficacy has been validated in worldwide surgical fields. However, further improvements are required to the traditional manipulation methods, which cannot control an endoscope and surgical instruments simultaneously. This study proposes a speech recognition control interface (SRCI) for controlling the endoscope via speech commands while manipulating surgical instruments to replace the traditional method.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Obstetrics and Gynecology, Faculty of Medicine, Kagoshima University, Kagoshima 890-8520, Japan.
: This study aims to evaluate and compare the safety and efficacy of the da Vinci Xi and hinotori™ SRS robot-assisted surgical systems for gynecologic disorders. : We conducted a retrospective study of 401 cases (43 benign uterine tumors; 88 pelvic organ prolapses; 270 low-risk endometrial cancers) of robot-assisted surgery performed at Kagoshima University Hospital between January 2017 and October 2024. Surgical factors such as the operative time, blood loss, and complication rates were analyzed and compared between the da Vinci Xi (332 cases) and hinotori™ SRS (69 cases) systems.
View Article and Find Full Text PDFCureus
December 2024
General Surgery, East Sussex Healthcare NHS Trust, Brighton and Hove, GBR.
Ectopic parathyroid glands result from abnormal migration during development. If not detected promptly, they can lead to persistent or recurrent primary hyperparathyroidism (pHPT). Inferior parathyroid glands are typically located in the anterior mediastinum, while superior parathyroid glands are often near the tracheoesophageal groove, both of which contribute to pHPT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!