A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative and qualitative investigation into the impact of focused ultrasound with microbubbles on the triggered release of nanoparticles from vasculature in mouse tumors. | LitMetric

Ultrasound-mediated microbubble destruction may enhance the release of nanoparticles from vasculature to tumor tissues. In this study, we used four different sizes of lipid-coated CdSe quantum dot (LQD) nanoparticles ranging from 30 to 180 nm, 1.0-MHz pulsed focused ultrasound (FUS) with a peak acoustic pressure of 1.2-MPa, and an ultrasound contrast agent (UCA; SonoVue) at a dose of 30 microL/kg to investigate any enhancement of targeted delivery. Tumor-bearing male Balb/c mice were first injected with UCA intravenously, were then sonicated at the tumors with FUS, and were finally injected with 50 microL of the LQD solution after the sonication. The mice were sacrificed about 24h after the sonication, and then we quantitatively and qualitatively evaluated the deposition of LQDs in the tumors by using graphite furnace atomic absorption spectrometry (GF-AAS), photoluminescence spectrometry (PL), and harmonic generation microscopy (HGM). Further, immunoblotting analysis served to identify the biochemical markers reflecting the vascular rupture. The experimental results show that the amount of LQDs deposited in tumor tissues was greater in cases of FUS/UCA application, especially for smaller LQDs, being 4.47, 2.27, 0.99, and 0.82 (microg Cd)/(g tumor) for 30, 80, 130, and 180 nm of LQDs, respectively; compared to 1.12, 0.75, 0.26, and 0.34 (microg Cd)/(g tumor) in absence of FUS/UCA. The immunoblotting analysis further indicates that FUS-induced UCA oscillation/destruction results in rupture areas in blood vessels increasing the vascular permeability and thus justifying for the higher quantity of nanoparticles deposited in tumors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jconrel.2010.05.033DOI Listing

Publication Analysis

Top Keywords

focused ultrasound
8
release nanoparticles
8
nanoparticles vasculature
8
tumor tissues
8
immunoblotting analysis
8
microg cd/g
8
cd/g tumor
8
quantitative qualitative
4
qualitative investigation
4
investigation impact
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!