A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An alternative technique of implanting a nontransvenous implantable cardioverter-defibrillator system in adults with no or limited venous access to the heart. | LitMetric

Background: In some patients at high risk for sudden cardiac death, a transvenous implantable cardioverter-defibrillator (ICD) cannot be implanted owing to limited vascular access. These patients can benefit from a nontransvenous defibrillation system consisting of a rate-sensing lead attached to the epicardium and a subcutaneous (SQ) array.

Objective: We examine the feasibility, safety, and clinical circumstances requiring implant of nontransvenous defibrillation system in adults.

Methods: Eight patients received an ICD system composed of an SQ array and either a chronic endocardial rate/sense lead (n = 5) or a new epicardial rate/sense lead (n = 3) for primary (n = 2) or secondary (n = 6) prevention. The obstacles to transvenous ICD implantation included recurrent endovascular lead infections (n = 1), congenital heart disease (n = 4), and superior vena cava occlusion (n = 3). The array was tunneled posteriorly, and the epicardial rate-sensing leads were implanted by left lateral minithoractomy. Four patients also required left ventricular pacing.

Results: Successful defibrillation was obtained in all patients at 29 ± 2.6 J. There were no major cardiovascular complications. Over a mean follow-up of 545 ± 204 days there was one appropriate and no inappropriate shocks. None of the patients required system revision. There were no significant changes in impedance, pacing threshold, or ventricular sensing observed with the epicardial leads and no change in high-voltage impedance.

Conclusions: The nontransvenous defibrillation system described is an effective technique in an adult population with acceptable pacing and defibrillation threshold.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2010.07.006DOI Listing

Publication Analysis

Top Keywords

nontransvenous defibrillation
12
defibrillation system
12
implantable cardioverter-defibrillator
8
rate/sense lead
8
patients required
8
system
6
patients
6
defibrillation
5
alternative technique
4
technique implanting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!