Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Sputum induction is a tool recommended for the assessment of airway inflammation and disease management. Currently, its use is limited because samples need to be processed within 3 h of induction (ie, while cells are viable); therefore, this procedure is unavailable to most clinicians.
Objective: To develop a fixation method for induced sputum samples that allows for a delay in processing while maintaining sample integrity and not altering the standard processing method.
Methods: Sputum samples were collected and split into three portions: a fresh sample processed using the routine method (within 3 h, using dithiothreitol); fixation in alcohol followed by delayed processing using the routine method (within 48 h to 72 h, using dithiothreitol); and fixation in formaldehyde followed by delayed processing using an alternative method (within 48 h to 72 h, using proteolysis). For each method, cytospins were prepared and differential cell counts were performed.
Results: Fixation in alcohol provides accurate measures of eosinophils and macrophages, but not neutrophils. Formaldehyde fixation provides accurate measures of neutrophils and macrophages, but not eosinophils.
Discussion: Alcohol fixation is a superior method for eosinophil quantification. It requires alteration of standardized methods for sputum sample processing and should be recommended for monitoring eosinophilic airway disease in settings where immediate processing of a sputum sample is not possible.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2900142 | PMC |
http://dx.doi.org/10.1155/2010/217678 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!