Example-based human motion denoising.

IEEE Trans Vis Comput Graph

Texas A&M University, College Station, TX, USA.

Published: September 2010

With the proliferation of motion capture data, interest in removing noise and outliers from motion capture data has increased. In this paper, we introduce an efficient human motion denoising technique for the simultaneous removal of noise and outliers from input human motion data. The key idea of our approach is to learn a series of filter bases from precaptured motion data and use them along with robust statistics techniques to filter noisy motion data. Mathematically, we formulate the motion denoising process in a nonlinear optimization framework. The objective function measures the distance between the noisy input and the filtered motion in addition to how well the filtered motion preserves spatial-temporal patterns embedded in captured human motion data. Optimizing the objective function produces an optimal filtered motion that keeps spatial-temporal patterns in captured motion data. We also extend the algorithm to fill in the missing values in input motion data. We demonstrate the effectiveness of our system by experimenting with both real and simulated motion data. We also show the superior performance of our algorithm by comparing it with three baseline algorithms and to those in state-of-art motion capture data processing software such as Vicon Blade.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TVCG.2010.23DOI Listing

Publication Analysis

Top Keywords

motion data
28
motion
16
human motion
16
motion denoising
12
motion capture
12
capture data
12
filtered motion
12
data
10
noise outliers
8
objective function
8

Similar Publications

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Influence of pelvic position on shoulder range of motion.

BMC Musculoskelet Disord

January 2025

Lecturer of Physical Therapy, Basic Science Department, Faculty of Physical Therapy, Suez University, Suez, Egypt.

Background: pelvis and shoulder are deeply integrated. They are connected by myofascial slings. The pelvic and spinal posture affects the position of the scapula and the activity of its muscles and affects acromio-humeral distance and so that affects shoulder movement.

View Article and Find Full Text PDF

Background: Mobile Health Clinics (MHCs) are an alternate form of healthcare delivery that may ameliorate current rural-urban health disparities in chronic diseases and have downstream impacts on the health system by reducing costs. Evaluations of providers' time allocation on MHCs are scarce, hindering knowledge transfer related to MHC implementation strategies.

Methods: Retrospective economic cost was assessed using business ledgers and expert assessments in 2023 US Dollar (USD) from 2022 to 2023.

View Article and Find Full Text PDF

Music can evoke powerful emotions in listeners. However, the role that instrumental music (music without any vocal part) plays in conveying extra-musical meaning, above and beyond emotions, is still a debated question. We conducted a study wherein participants (N = 121) listened to twenty 15-second-long excerpts of polyphonic instrumental soundtrack music and reported (i) perceived emotions (e.

View Article and Find Full Text PDF

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!