Purpose: To evaluate the safety and efficacy of a hybrid flexor carpi radialis (FCR) approach for volar plate osteosynthesis of displaced distal radius fractures with concurrent prophylactic carpal tunnel release (CTR) in patients without preoperative signs or symptoms of acute carpal tunnel syndrome secondary to the fracture.

Methods: A total of 68 displaced distal radius fractures in 65 eligible adult patients (35 men, 30 women; mean age, 48.6 +/- 15.4 y) who had volar plate osteosynthesis and concomitant prophylactic CTR through a hybrid FCR approach by a single surgeon were included in this study. A systematic chart review and subsequent telephone questionnaire were performed to identify any postoperative median nerve dysfunction, recurrent motor or palmar cutaneous branch injury, tendon injury, or other complications directly related to the approach.

Results: Reported symptoms consistent with late median nerve dysfunction were identified in 2 cases; however, no patients in this series required additional surgery for early or late median neuropathy. Furthermore, no cases of median nerve sensory or motor branch injury or tendon injury were identified. No other unforeseen complications specifically related to the approach were observed.

Conclusions: Volar plate osteosynthesis of distal radius fractures with a concurrent prophylactic CTR can be safely performed through the described hybrid FCR approach in patients without signs or symptoms of acute CTS. Routine release of the transverse carpal ligament with the hybrid FCR approach at the time of fracture fixation might reduce the incidence of postoperative median nerve dysfunction.

Type Of Study/level Of Evidence: Therapeutic IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2010.03.043DOI Listing

Publication Analysis

Top Keywords

volar plate
16
plate osteosynthesis
16
distal radius
16
radius fractures
16
fcr approach
16
median nerve
16
fractures concurrent
12
concurrent prophylactic
12
carpal tunnel
12
hybrid fcr
12

Similar Publications

Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.

Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.

Materials And Methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022.

View Article and Find Full Text PDF

There are many approaches to the wrist both volar and dorsal, depending on the injury at hand. The design of the volar locking plate has created a rise in distal radius fractures being treated using a volar FCR approach and its modifications. It does, however, have limitations in visualization of the volar ulnar corner of the radius.

View Article and Find Full Text PDF

Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study.

J Hand Surg Eur Vol

January 2025

Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.

Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).

View Article and Find Full Text PDF

Elderly patients with distal radius fractures (DRFs) pose a significant medical challenge due to their high incidence and related healthcare costs. Both surgical methods like volar plate fixation and conservative approaches such as casting are common, yet their relative effectiveness remains unclear. This review and meta-analysis compare surgical and conservative treatments, focusing on wrist functionality, upper extremity performance, grip strength, and pain after one year.

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!