The purpose of the present study was to investigate cataractogenesis and recovery of lens damage after in vivo close to threshold ultraviolet (UV)-B radiation around 300 nm. Eighty six-week-old albino Sprague-Dawley rats were familiarized to a rat restrainer five days prior to exposure. Groups of non-anesthetized rats were exposed unilaterally to 8 kJ/m(2) UVR-300 nm. The animals were sacrificed at 1, 7, 48 and 336h following exposure. The lenses were extracted for imaging of dark-field lens macro anatomy and measurement of intensity of forward lens light scattering to quantify lens opacities. Three exposed lenses and one non-exposed lens from each time interval were examined with light and transmission electron microscopy (TEM). Macro anatomy and lens light scattering revealed that all contralateral non-exposed lenses were clear. The degree of lens opacity (difference in lens light scattering between exposed and non-exposed lenses) increased during the 336h, reaching a plateau towards the end of the observation period. Light microscopy and TEM demonstrated that apoptotic features appeared in the epithelium already 1h after UVR exposure, and small vacuoles were seen in the outer cortex. Epithelial damage occurs during the first 48h after exposure and is followed by regenerative repair at 336h post-exposure. Apoptotic epithelial cells were phagocytized by adjacent epithelial cells. Cortical fiber cells exhibited increasing damage throughout the observation period without any clear repair after 336h. In conclusion, acute UVR-induced cataract is partly a reversible. Lens epithelium is a primary target for UVR exposure. Damage to cortical fiber cells remained irreversible.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.exer.2010.06.009 | DOI Listing |
J Funct Biomater
December 2024
Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.
Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality.
View Article and Find Full Text PDFCureus
November 2024
Ophthalmology, International University of Health and Welfare, Chiba, JPN.
Keratoconus is a condition that causes progressive thinning and anterior protrusion of the cornea. Because of its irregular astigmatism, mild to moderate keratoconus is corrected with hard contact lenses (HCLs), but blepharoptosis due to the long-term wearing of HCLs is often a problem. In this study, we investigated blepharoptosis in HCL wearers with keratoconus.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
College of Electrical and Information Engineering, SANYA Offshore Oil and Gas Research Institute, Northeast Petroleum University, Daqing 163318, China.
Integrating ZnS:Cu@AlO/polydimethylsiloxane (PDMS) flexible matrices with optical fibers is crucial for the development of practical passive sensors. However, the fluorescence coupling efficiency is constrained by the small numerical aperture of the fiber, leading to a reduction in sensor sensitivity. To mitigate this limitation, a microsphere lens was fabricated at the end of the multimode fiber, which resulted in a 21.
View Article and Find Full Text PDFInt J Emerg Med
December 2024
Mejiro University Ear Institute Clinic, 320 Ukiya, Iwatsuki-ku, Saitama-shi, Saitama, 339-8501, Japan.
Background: Reduction of spontaneous nystagmus by fixation, a characteristic feature of peripheral nystagmus, is important for differentiating between peripheral and central vestibular disorders. In the emergency room, Frenzel goggles are recommended to observe spontaneous nystagmus for the differential diagnosis of acute vestibular syndrome. We developed a portable loupe with a Fresnel lens to observe nystagmus.
View Article and Find Full Text PDFRev Sci Instrum
December 2024
SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.
We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!