A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Femur flap for tibial reconstruction: percent circumference required to convey a mechanical advantage over the fibula. | LitMetric

The fibula flap is commonly used to reconstruct the tibia. This has risk of postoperative fracture despite long-term non-weight bearing. A flap using noncircumferential distal femur is proposed. This study is to determine the circumference of femur required to produce greater strength than the fibular flap. Femurs and fibulas were harvested from eight cadavers. The structural strength of fibula and femur flaps was assessed using three-point bend. Compression testing was performed on osteotomized and whole femurs to assess donor site morbidity. The 35% flap (mean maximum force at fracture 869 N) was not significantly stronger than the fibula flap (626 N; P > 0.05). The 40% flap (1225 N) was significantly stronger than the fibula flap ( P < 0.01). There was no significant difference between forces at fracture for whole femurs (3978 N), femurs with 35% osteotomies (3604 N), and femurs with 40% osteotomies (3493 N; P = 0.87). Change occurred in the fracture pattern of femurs following osteotomies. Whole femurs consistently fractured at the femoral neck, and osteotomized femurs consistently fractured obliquely from the osteotomy. A flap consisting of 40% of the circumference of the distal femur exceeds the structural strength of the fibular flap. Taking such a flap changes the femur's structural integrity; fixation may be prudent following harvest.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0030-1261698DOI Listing

Publication Analysis

Top Keywords

fibula flap
12
flap
10
distal femur
8
strength fibular
8
fibular flap
8
femurs
8
structural strength
8
osteotomized femurs
8
stronger fibula
8
femurs consistently
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!