A multi-angle lensfree holographic imaging platform that can accurately characterize both the axial and lateral positions of cells located within multi-layered micro-channels is introduced. In this platform, lensfree digital holograms of the micro-objects on the chip are recorded at different illumination angles using partially coherent illumination. These digital holograms start to shift laterally on the sensor plane as the illumination angle of the source is tilted. Since the exact amount of this lateral shift of each object hologram can be calculated with an accuracy that beats the diffraction limit of light, the height of each cell from the substrate can be determined over a large field of view without the use of any lenses. We demonstrate the proof of concept of this multi-angle lensless imaging platform by using light emitting diodes to characterize various sized microparticles located on a chip with sub-micron axial and lateral localization over approximately 60 mm(2) field of view. Furthermore, we successfully apply this lensless imaging approach to simultaneously characterize blood samples located at multi-layered micro-channels in terms of the counts, individual thicknesses and the volumes of the cells at each layer. Because this platform does not require any lenses, lasers or other bulky optical/mechanical components, it provides a compact and high-throughput alternative to conventional approaches for cytometry and diagnostics applications involving lab on a chip systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2898907PMC
http://dx.doi.org/10.1364/OE.18.009690DOI Listing

Publication Analysis

Top Keywords

multi-angle lensless
8
imaging platform
8
axial lateral
8
located multi-layered
8
multi-layered micro-channels
8
digital holograms
8
field view
8
lensless imaging
8
lensless digital
4
digital holography
4

Similar Publications

Lensless systems based on ptychographic imaging can simultaneously achieve a large field of view and high resolution while having the advantages of small size, portability, and low cost compared to traditional lensed imaging. However, lensless imaging systems are susceptible to environmental noise and have a lower resolution of individual images than lens-based imaging systems, which means that they require a longer time to obtain a good result. Therefore, in this paper, to improve the convergence rate and robustness of noise in lensless ptychographic imaging, we propose an adaptive correction method, in which we add an adaptive error term and noise correction term in lensless ptychographic algorithms to reach convergence faster and create a better suppression effect on both Gaussian noise and Poisson noise.

View Article and Find Full Text PDF

Organoids, the 3D culture systems derived from stem cells, are promising models for human organs. However, organoid study requires large-volume imaging with single cell resolution, which is beyond the spatial bandwidth limit of conventional optical microscopy. Herein, we propose a lensless holographic microscope empowered with a time and memory-saving algorithm.

View Article and Find Full Text PDF

Multi-angle structured illumination lensless (MASIL) microscopy enables high-resolution image recovery over a large field of view. Successful image recovery of MASIL microscopy, however, relies on an accurate knowledge of the multi-angle illumination. System misalignments and slight deviations from the true illumination angle may result in image artifacts in reconstruction.

View Article and Find Full Text PDF

Lensless imaging is a technique that records diffraction patterns without using lenses and recovers the complex field of object via phase retrieval. Robust lensless phase retrieval process usually requires multiple measurements with defocus variation, transverse translation or angle-varied illumination. However, making such diverse measurements is time-consuming and limits the application of lensless setup for dynamic samples.

View Article and Find Full Text PDF

On-chip Microscopy Using Random Phase Mask Scheme.

Sci Rep

November 2017

State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China.

In this study, a simple and novel phase-retrieval scheme is implemented using multi-angle illumination to enhance the resolution of lensless microscopy. A random-phase mask (from 0 to 2π) precedes the sample to encode the information at the sensor plane. The sample is illuminated with multiple angles that are symmetrical along the optical axis of the system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!