Objective: The purpose of this study was to evaluate ductus venosus flow velocities and a possible relationship with the type of cardiac defect in fetuses with increased nuchal translucency (NT).

Methods: Seventy-two fetuses with normal NT and 137 fetuses with increased NT (>95th percentile) were evaluated. The ductus venosus pulsatility index for veins (PIV), late diastolic velocity (velocity during atrial contraction [a-V]), and intracardiac velocities were evaluated. In cases of pregnancy termination, a postmortem examination was performed. Cardiac defects were grouped into septal defects, left and right inflow obstruction, left and right outflow obstruction, and other defects. Data were evaluated by multilevel analysis.

Results: A cardiac defect was found in 45 fetuses with increased NT. Fetuses with increased NT showed a higher ductus venosus PIV and a lower a-V compared to fetuses with normal NT (P < .05). Within the group of fetuses with increased NT, a higher PIV and a lower a-V were found in cases with a cardiac defect compared to cases with a normal heart (P < .001). No differences in PIV and a-V were found between the types of cardiac defects. Intracardiac velocities showed no differences between fetuses with normal and increased NT, irrespective of the presence of a cardiac defect.

Conclusions: Ductus venosus flow velocities in fetuses with increased NT are not related to a certain type of cardiac defect. This indicates that the altered ductus venosus flow velocities found in fetuses with increased NT cannot be explained by cardiac failure due to a specific altered cardiac anatomy.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2010.29.7.1051DOI Listing

Publication Analysis

Top Keywords

fetuses increased
32
ductus venosus
24
venosus flow
16
cardiac defect
16
type cardiac
12
flow velocities
12
fetuses normal
12
fetuses
11
cardiac
10
increased
9

Similar Publications

Hematologic Complications of Pregnancy.

Eur J Haematol

January 2025

Division of Hematology and Medical Oncology, Oregon Health & Science University, Portland, Oregon, USA.

Hematologic complications are common in pregnancy and can significantly impact both maternal and fetal health. Recognizing and treating these complications can be challenging due to the limited evidence available to guide clinical consultants. Iron deficiency anemia is the most prevalent hematologic issue in pregnancy and often occurs due to increased maternal blood volume and the nutritional demands of the growing fetus.

View Article and Find Full Text PDF

Background: Aspirin has proved its efficacy in reducing the rate of preeclampsia in singleton pregnancy, however, there is discrepancy about the efficient dosage that should be used. While some societies recommend daily 75-81mg, others recommend higher dosage (160mg). This discrepancy is due to the lack of randomized controlled studies that compare these two dosages.

View Article and Find Full Text PDF

Characterizing thyroid follicles histogenesis in the human fetuses: A morphological approach.

Tissue Cell

December 2024

Department of Anatomy, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India. Electronic address:

Thyroid gland which is responsible for the maintenance of metabolism and growth is derived from thyroglossal duct, an outpocketing of foregut. The microscopic study of thyroid gland during development in first, second and third trimesters has utmost significance to understand the several developmental thyroid disorders metabolically and structurally. This study is descriptive observational study carried in tissue sections taken from thyroid gland of still birth and spontaneously aborted human fetuses of first, second and third trimester.

View Article and Find Full Text PDF

Background: Operative delivery is a technique used during vaginal or cesarean birth to facilitate the patient's labor course through the assistance of a vacuum extractor. This method is increasingly used compared with forceps. This study aimed to investigate the forced effects of vacuum extractors comprising vacuum cups with different thicknesses on the fetal head and the vacuum extractor during vacuum-assisted delivery and to determine the optimal thickness for reducing the failure rate and minimizing neonatal and maternal morbidity.

View Article and Find Full Text PDF

Objectives: The size, shape, and contractility of the heart's atrial chambers have not been evaluated in fetuses with growth restriction (FGR) or who are small-for-gestational-age (SGA) as defined by the Delphi consensus protocol. This study aimed to examine the atrial chambers using speckle tracking analysis to identify any changes that may be specific for either growth disturbance.

Methods: Sixty-three fetuses were evaluated with an estimated fetal weight <10th percentile who were classified as FGR or SGA based on the Delphi consensus protocol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!