Application of a novel dose-uncertainty model for dose-uncertainty analysis in prostate intensity-modulated radiotherapy.

Int J Radiat Oncol Biol Phys

University of Florida Proton Therapy Institute, University of Florida, Jacksonville, FL, USA.

Published: November 2010

AI Article Synopsis

Article Abstract

Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT).

Methods And Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty-based plan evaluation tools were introduced: confidence-weighted dose-volume histogram, confidence-weighted dose distribution, and dose-uncertainty-volume histogram.

Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose.

Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2010.01.063DOI Listing

Publication Analysis

Top Keywords

dose uncertainty
24
dose-uncertainty model
20
dose-uncertainty
8
prostate intensity-modulated
8
intensity-modulated radiotherapy
8
dose
8
intrafraction interfraction
8
imrt plans
8
plan evaluation
8
uncertainty 95%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!