A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Heart failure: the challenge of selecting patients for implantable cardioverter defibrillator therapy. | LitMetric

Patients with heart failure die predominantly of progressive pump failure or sudden cardiac death. Therefore, it is attractive to believe that an implantable cardioverter defibrillator (ICD) will dramatically reduce mortality by reducing sudden death. However, unfortunately it is not that simple; sudden death is not the same as ICD-preventable death. While ICD prophylaxis always reduces arrhythmic death, it does not always reduce all-cause mortality due to competing risks. Importantly, an arrhythmia may be a marker for heart failure decompensation, with patients at increased risk of heart failure death following shock therapy. Randomized trials have now demonstrated the potential benefits of ICDs in selected patients with left ventricular dysfunction, yet they have also failed to demonstrate benefit in populations where one might have expected to see benefit (e.g., early post-myocardial infarction). Device therapy can offer heart failure patients much more than just a simple shock box. The addition of a left ventricular lead to allow biventricular pacing (cardiac resynchronization therapy) improves symptoms and prolongs life in selected patients with QRS prolongation. Newer technologies allow remote monitoring through the device, which offers the potential to recognize heart failure decompensation or arrhythmias early so that appropriate treatment can be instituted. However, deciding which patient should receive an ICD remains one of the most challenging questions in cardiovascular medicine.

Download full-text PDF

Source
http://dx.doi.org/10.1586/erd.10.18DOI Listing

Publication Analysis

Top Keywords

heart failure
24
implantable cardioverter
8
cardioverter defibrillator
8
sudden death
8
failure decompensation
8
selected patients
8
left ventricular
8
heart
6
patients
6
failure
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!