Purpose: The concept of "prosthetic-driven implantology" may be considered a turning point in the history of modern dental implantology. On the basis of this sophisticated approach, the available bone and the optimal prosthetic position of the future restoration are checked before surgical intervention. However, the major drawback of today's prosthodontic discipline is that it is inherently 2-dimensional in nature, which may prevent the appropriate treatment; this problem can be overcome by the 3-dimensional capability of a computer-assisted approach when performed judiciously. It was proposed that this technique has the potential to provide a high level of safety and accuracy in comparison to traditional surgical procedures.

Materials And Methods: Using a novel approach, we performed modified flapless implant surgery accompanied by a simultaneous sinus-lifting procedure. The technique used a 3-dimensional life-sized computer-aided design/computer-aided manufacturing (CAD/CAM) model prepared from the computed tomography images for prosthetic/surgical diagnosis and treatment planning.

Results: The procedure of implant planning, model surgery, and sinus floor augmentation in this sophisticated flapless surgical approach has the potential to provide substantial benefits for both patients and practitioners.

Conclusions: The versatility of the described technique not only allows more accurate implementation of the treatment plan to the patient's mouth but also may offer many additional significant benefits, including the use of custom surgical guides, life-sized bone model manipulation, and surgical rehearsal, all of which are very difficult to achieve with current traditional procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joms.2010.02.002DOI Listing

Publication Analysis

Top Keywords

modified flapless
8
implant surgery
8
approach performed
8
potential provide
8
surgical
6
flapless dental
4
dental implant
4
surgery planning
4
treatment
4
planning treatment
4

Similar Publications

A multifaceted study compared transgingival (flapless) implant placement with conventional flapped placement, which employed clinical, radiographic, biochemical, and patient-centered parameters. The study was approved by the institutional ethics committee and was conducted according to the ethical standards in the 1964 Declaration of Helsinki and its amendments. Seventy-five implants were placed, 37 by flapless method (group 1) and 38 by flapped method (group 2).

View Article and Find Full Text PDF

Plain flaps (PFs) significantly increase camber, enhancing lift and aerodynamic performance when deployed. In Darrieus Vertical Axis Wind Turbines (VAWTs), which perform efficiently in low-speed, turbulent wind conditions, structural modifications like PFs can improve efficiency. This study explores plain flaps with 10-20-degree deflections at different chord lengths to enhance the NACA 2412 aerofoil's performance.

View Article and Find Full Text PDF

Background: It is important to prognosticate the hard- and soft-tissue alterations in immediate and delayed implants, as inadequacy can lead to complications affecting the long-term survival of the implant. Therefore, the purpose of this study was to evaluate and compare the hard- and soft-tissue changes in immediate and delayed posterior implants with a flapless approach.

Materials And Methods: With an equal allocation ratio, the study included 46 patients requiring implant treatment in the posterior segment, including the premolars and molars.

View Article and Find Full Text PDF

Objectives: This study aimed to systematically compare the effects of flapless and flapped implantations on the surrounding soft tissues of dental implants.

Methods: Nine databases were searched, including PubMed, Embase, Cochrane Library, Web of Science, Clinical Trials, OpenGrey, OpenDoar, Scopus, and Ovid, from January 1, 2013, to August 27, 2023. Randomized controlled trials comparing flapless implantation with flapped implantation for restoration of missing teeth were included.

View Article and Find Full Text PDF

The aim of this study is to describe a modified technique for internal refixation of dislocated scleral-sutured polymethylmethacrylate (PMMA) intraocular lenses (IOLs) with eyelets. Three-port pars plana vitrectomy was performed. Through the scleral fixation site, a 30-gauge needle loaded with an 8-0 polypropylene suture was inserted into the vitreous cavity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!