Purpose: We reviewed our experience with laparoscopic cryoablation (LCA) and percutaneous cryoablation (PCA) in the management of small renal tumors and compared clinical outcomes, short-term oncologic results, and patient complications.

Patients And Methods: A retrospective comparison of two prospectively collected oncologic databases was performed. Ninety patients underwent PCA for 99 lesions and 81 patients underwent an LCA for 97 lesions. Patient characteristics, perioperative data, and tumor characteristics were recorded including age, estimated blood loss, complication rate, tumor size, and tumor pathology.

Results: Patients in both the PCA and LCA groups had similar demographic and tumor characteristics. The PCA group had two major complications (2%), and the LCA group had three major complications (3.7%) (P = 0.374). In the LCA group, estimated blood loss was associated with tumor location with hilar tumor demonstrating a significantly higher mean blood loss (191 mL) compared with endophytic, mesophytic, and exophytic tumors (70 mL, 71 mL, 73.5 mL), respectively (P = 0.05). Malignancies rated in the PCA and LCA groups were 50.5% and 60.0%, respectively (P < 0.05). In the PCA group, nine (9.1%) patients demonstrated treatment failure with a persistent enhancement in the ablation bed. All nine were treated with a subsequent PCA. One patient had subsequent tumor bed enhancement and underwent an open radical nephrectomy. Treatment failed in three (3.1%) patients in the LCA cohort (incomplete ablation or recurrence).

Conclusions: With short-term follow-up, both LCA and PCA are safe and effective treatments for small renal masses. Patients undergoing PCA had a reduced hospital stay and a lower surgical complication rate, albeit with an elevated re-treatment rate. Long-term data is needed to establish long-term oncologic efficacy. Renal function did not significantly change in patients after cryoablation, including patients with a solitary kidney.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2010.0067DOI Listing

Publication Analysis

Top Keywords

comparison percutaneous
4
percutaneous laparoscopic
4
laparoscopic renal
4
renal cryoablation
4
cryoablation small
4
comparison
1
laparoscopic
1
renal
1
cryoablation
1
small
1

Similar Publications

Background/Aims: To evaluate invasive treatment outcomes for hepatocellular carcinoma (HCC) in patients aged over 90 years. Materials and methods: Twenty-six patients were included. Information on backgrounds, course of treatment, outcomes, and changes in Child-Pugh (CP) score and performance status (PS), as well as a comparison of treatment-related complications and 2-year survival after treatment, were retrospectively examined and compared with 311 patients aged under 90 years who were matched under the same conditions.

View Article and Find Full Text PDF

Purpose: This study evaluates the feasibility of utilizing robotic-assisted bronchoscopy with cone beam computed tomography (RB-CBCT) platform to perform low-dose-rate brachytherapy implants (LDR-BT) in a mechanically ventilated human cadaveric model. Post-implant dosimetry was compared to standard stereotactic body radiation therapy plans (SBRT).

Materials And Methods: The RB-CBCT platform was used to place inert LDR-BT seeds into mechanically ventilated human cadavers with percutaneously injected pseudotumors.

View Article and Find Full Text PDF

Rationale: The biodegradable polymer BioMatrix Alpha™ stent contains biolimus A9 drug which is sirolimus derivative increase in lipophicity. The biodegradable polymer sirolimus eluting Combo™ stent is a dual-therapy sirolimus-eluting and CD34+ antobody coated stent capturing endothelial progenitor cells (EPCs).

Hypothesis: The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 BioMatrix Alpha ™ stent is noninferior to the biodegradable polymer sirolimus eluting Combo™ stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).

View Article and Find Full Text PDF

Background: Despite the high mortality of cardiogenic shock after acute myocardial infarction (AMI-CS), the comparative efficacy and safety of mechanical circulatory support (MCS) in patients with AMI-CS is unknown. This study aimed to compare the efficacy and safety of various MCS with initial medical therapy for AMI-CS patients.

Methods: We searched PubMed and EMBASE in July 2024.

View Article and Find Full Text PDF

Purpose: This research aimed to develop and assess a Lipiodol Pickering emulsion containing anti-Programmed cell Death Ligand 1 (PD-L1) antibodies through in vitro experiments.

Materials And Methods: The emulsion was created by combining Lipiodol with poly (lactic-co-glycolic acid) (PLGA) nanoparticles and anti-PD-L1 antibodies. Confocal laser microscopy was used to evaluate the encapsulation of the antibodies within the Pickering emulsion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!