The paradigm of sine-wave electrical stimuli has been used for sensory neurological assessment in humans. In the present study, we applied the paradigm to the dog for the quantitative assessment of sensory function. Sine-wave electrical current stimuli at frequencies of 2000, 250, and 5Hz were delivered to bipolar electrodes attached to the skin surface of the hind paws. The stimulation intensity was gradually increased, and the minimum intensity required to elicit the lifting behavior in the stimulated paw was determined as current threshold (CT) for each of the three frequencies. Dogs consistently showed the lifting behavior at CTs without showing aversive behaviors such as vocalization and wriggling. The baseline CTs (mean+/-SEM, n=12) were 4430+/-110microA for CT2000, 2215+/-173microA for CT250, and 2305+/-152microA for CT5. The CTs immediately increased after bolus intravenous injection of fentanyl at 10microg/kg, although the significant increase disappeared within 1h. The time course for the CTs was parallel to that of plasma fentanyl concentration. In conclusion, the present study applied the paradigm of transcutaneous sine-wave electrical stimuli to the dog, and used the hind paw lifting as endpoint behavior. This paradigm is simple, non-invasive, useful in the assessment of sensory function, and can be adapted to investigate the pharmacokinetics/pharmacodynamics relation of drugs. Further studies are needed to give the conclusive interpretation of the endpoint behavior.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.physbeh.2010.05.019 | DOI Listing |
Micromachines (Basel)
November 2024
School of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.
The actuator is a critical component of the micromanipulator. By utilizing the properties of expansion and contraction, the piezoelectric actuator enables the manipulator to handle and grasp miniature objects during micromanipulation. However, in piezoelectric ceramic disc actuators with conventional surface electrode configurations, the actuating force generated in the radial direction is relatively limited.
View Article and Find Full Text PDFSci Rep
October 2024
Department of Textile Machine Design, Faculty of Mechanical Engineering, Technical University of Liberec, Czech Republic, adress: Studentska 1402/2, Liberec, 461 17, Czech Republic.
Pain Rep
October 2024
Department of Experimental Pain Research, Mannheim Center for Translational Neuroscience, Medical Faculty Mannheim, University of Heidelberg, Heidelberg, Germany.
Rev Sci Instrum
February 2024
Western Michigan University, College of Engineering and Applied Science, Kalamazoo, Michigan 49009, USA.
To completely characterize the evolving state of a plasma, diagnostic tools that enable measurements of the time-resolved behavior are required. In this study, a gridded ion source with superimposed oscillations was utilized to verify the functionality of a high-speed retarding potential analyzer (HSRPA), at frequencies equivalent to the low frequency oscillations occurring in Hall effect thrusters (HETs). The verification of this device provides an effective alternative to existing diagnostics for measuring time-resolved ion energies.
View Article and Find Full Text PDFSensors (Basel)
January 2024
Department of Electrical & Computer Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
Micromachined electric field mills have received much interest for the measurement of DC fields; however, conventional designs with lateral moving shutters could have shutter lifting in the presence of strong fields, which affects their performance. This paper presents a MEMS electric field mill utilizing a vertical movement shutter to address this issue. The sensor is designed and fabricated based on a flexible PCB substrate and is released using a laser-cutting process.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!