Different methods have been described by numerous investigators for experimentally assessing the kinematics of cervical artificial discs. However, in addition to understanding how artificial discs affect range of motion, it is also clinically relevant to understand how artificial discs affect segmental posture. The purpose of this paper is to describe novel considerations and methods for experimentally assessing cervical spine postural control in the laboratory. These methods, which include mechanical testing, cadaveric testing, and computer modeling studies, are applied in comparing postural biomechanics of a novel postural control arthroplasty (PCA) device versus standard ball-and-socket (BS) and ball-in-trough (BT) arthroplasty devices. The overall body of evidence from this group of tests supports the conclusion that the PCA device does control posture to a particular lordotic position, whereas BS and BT devices move freely through their ranges of motion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2010.3.FOCUS1063 | DOI Listing |
J Spine Surg
December 2024
Spinal Surgery Team, Wirbelsäulenzentrum Ostschweiz AG, St. Gallen, Switzerland.
Background: The objective of this report is to present a case of two cervical spine artificial discs (Bryan Cervical Disk) that completely disappeared within 6 months as a result of a high-energy trauma more than 10 years after the initial surgery. Implant dislocation is a known complication in artificial cervical disc replacement. However, this report presents the case of an exceptional migration path with esophageal ingrowth and rectal excretion, not only for one artificial disc but for two at different times It highlights the need for long-term follow-up examinations after artificial cervical disc arthroplasty (ACDA).
View Article and Find Full Text PDFMethodsX
June 2025
Assistant Professor, Department of Electronics and Communication Engineering, Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology, Tamil Nadu, 600062, India.
Glaucoma, a severe eye disease leading to irreversible vision loss if untreated, remains a significant challenge in healthcare due to the complexity of its detection. Traditional methods rely on clinical examinations of fundus images, assessing features like optic cup and disc sizes, rim thickness, and other ocular deformities. Recent advancements in artificial intelligence have introduced new opportunities for enhancing glaucoma detection.
View Article and Find Full Text PDFActa Biomater
January 2025
Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Via Terracini 28, 40131 Bologna, Italy. Electronic address:
Intervertebral disc (IVD) degeneration is suspected to affect the distribution of stress and strain near the vertebral endplates and in the underlying bone. This scenario is worsened by the presence of metastatic lesions on the vertebrae (primarily thoracic vertebrae (60-80 %)) which increase the risk of fracture. As such, this study aimed to evaluate the effect of IVD degeneration on the internal volumetric strains and failure modes of human metastatic vertebral bodies.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Mechanical Engineering Department, Dunarea de Jos University of Galati, 800201 Galati, Romania.
This paper presents an analysis of four clutch disc friction materials (from different manufacturers) used in manual transmissions. Scanning electron microscopy and energy-dispersive X-ray spectroscopy were employed for the microstructural and chemical characterisation of the friction materials. To reveal the tribological properties of the selected clutch discs, three measurements of the friction coefficient between the material and the cast iron disc were conducted.
View Article and Find Full Text PDFJ Esthet Restor Dent
January 2025
Department of Physiology and Pathology, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil.
Objectives: To evaluate the color change and trans-amelodentinal cytotoxicity of a 22% carbamide peroxide (CP) bleaching gel containing different concentration of manganese oxide (MnO).
Material And Methods: Enamel/dentin discs adapted to artificial pulp chambers were distributed according to treatments: CN-No treatment; CP22%-22%CP; CP22 + 2MnO-22%CP + 2 mg/mLMnO; CP22% + 6MnO-22%CP + 6 mg/mLMnO; CP22% + 10MnO-22%CP + 10 mg/mLMnO applied for 2 h for 15 days. Color change-CC (ΔE and ΔWI) (n = 8) was determined at 5, 10, and 15-day periods (ANOVA/Sidak).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!