Carotid-femoral pulse wave velocity is an established method for characterizing aortic stiffness, an individual predictor of cardiovascular mortality in adults. Normal pulse wave velocity values for the pediatric population derived from a large data collection have yet to be available. The aim of this study was to create a reference database and to characterize the factors determining pulse wave velocity in children and teenagers. Carotid-femoral pulse wave velocity was measured by applanation tonometry. Reference tables from pulse wave velocities obtained in 1008 healthy subjects (aged between 6 and 20 years; 495 males) were generated using a maximum-likelihood curve-fitting technique for calculating SD scores in accordance with the skewed distribution of the raw data. Effects of sex, age, height, weight, blood pressure, and heart rate on pulse wave velocity were assessed. Sex-specific reference tables and curves for age and height are presented. Pulse wave velocity correlated positively (P<0.001) with age, height, weight, and blood pressure while correlating negatively with heart rate. After multiple regression analysis, age, height, and blood pressure remained major predictors of pulse wave velocity. This study, involving >1000 children, is the first to provide reference values for pulse wave velocity in children and teenagers, thereby constituting a suitable tool for longitudinal clinical studies assessing subgroups of children who are at long-term risk of cardiovascular disease.

Download full-text PDF

Source
http://dx.doi.org/10.1161/HYPERTENSIONAHA.110.152686DOI Listing

Publication Analysis

Top Keywords

pulse wave
36
wave velocity
32
children teenagers
12
pulse
9
wave
9
reference values
8
values pulse
8
velocity
8
teenagers carotid-femoral
8
carotid-femoral pulse
8

Similar Publications

Mid-to-far-infrared (IR) spectral content is recorded using the novel self-balanced and self-phase-corrected electro-optical (EO) sampling arrangement. Self-balancing guarantees that the electric field emerging from the EO crystal yields a signal of zero via a Wollaston prism and balanced photodetector (i.e.

View Article and Find Full Text PDF

We propose and demonstrate a photonic compressive sensing (PCS) scheme for microwave signals using optical pulse random mixing, significantly enhancing both the compression ratio and operating frequency range. Unlike continuous-wave laser-based PCS systems, our approach mitigates the non-ideal characteristics of the pseudo-random binary sequence (PRBS), such as sloped edges and amplitude jitters, resulting in a more ideal compression process. Additionally, the high harmonic components of the optical pulses further facilitate wideband downconversion, improving the system's operating frequency range.

View Article and Find Full Text PDF

Objective: Globally, one in four pregnant women is classified as overweight or obese, based on their prepregnancy body mass index (BMI). Obese pregnant women are at increased risk of adverse pregnancy outcomes and long-term cardiovascular disease that occurs earlier in life. This study aimed to assess maternal hemodynamic and vascular parameters at 35-37 weeks' gestation, to understand the alterations that may occur in association with increased maternal BMI and gestational weight gain, and to evaluate obesity-related pregnancy outcomes.

View Article and Find Full Text PDF

Based on the symmetric initiation mechanism of double-wing cracks in coal rock mass induced by high-pressure electro-recoil water pressure, fracturing experiments have been performed on coal rock mass under different water pressures and discharge conditions using high-voltage electric pulse hydraulic fracturing devices. Combined with CT scans, the crack spatial distribution inside the post-break coal rock mass was analyzed and found that the edge of the water injection hole is prone to produce double-wing cracks along the drilling hole diameter. ABAQUS is used to verify the physical test and extend the test conditions, the geometric parameter change, morphological expansion rule and crack initiation mechanism of double-wing crack in coal rock mass under different discharge conditions and ground stress conditions are studied.

View Article and Find Full Text PDF

Accuracy of pulse wave velocity for screening coronary artery disease: a systematic review and meta-analysis.

Diagnosis (Berl)

January 2025

CarVasCare Research Group, Facultad de Enfermería de Cuenca, 16733 Universidad de Castilla-La Mancha , Cuenca, Spain.

Coronary artery disease (CAD) is the leading cause of cardiovascular events and showed high prevalence and healthcare costs in 2019. However, CAD screening for cardiovascular event prevention is invasive and expensive. This study aims to estimate the ability of a noninvasive method, pulse wave velocity (PWV), to detect the presence or absence of coronary artery disease in patients with suspected CAD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!