Design, implementation, and dosimetry analysis of an S-band waveguide in vitro system for the exposure of cell culture samples to pulsed fields.

Bioelectromagnetics

Departamento de Electromagnetismo y Teoría de Circuitos, Universidad Politécnica de Madrid, Spain.

Published: September 2010

The interaction between electromagnetic fields and biological media, particularly regarding very high power, short pulses as in radar signals, is not a fully understood phenomenon. In the past few years, many in vitro, cellular communications-oriented exposure studies have been carried out. This article presents a high-power waveguide exposure system capable of dealing with monochromatic, multicarrier or pulsed signals between 1.8 and 3.2 GHz (L- and S-band) with a pulse duration as low as 90 ns, minimum pulse repetition of 100 Hz, and maximum instantaneous power of 100 W. The setup is currently being used with a 2.2 GHz carrier modulated by 5 micros pulses with a 100 Hz repetition period and approximately 30 W of instantaneous power. After a worst-case temperature analysis, which does not account for conduction and convection thermal effects, the experiment's exposure is considered sub-thermal. Evaluation of the results through the specific absorption rate distribution is not considered sufficient enough in these cases. An electromagnetic field distribution analysis is needed. For monochromatic signals, the representation of the modulus of the electric and magnetic field components is proposed as a suitable method of assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bem.20579DOI Listing

Publication Analysis

Top Keywords

instantaneous power
8
design implementation
4
implementation dosimetry
4
dosimetry analysis
4
analysis s-band
4
s-band waveguide
4
waveguide vitro
4
vitro system
4
exposure
4
system exposure
4

Similar Publications

Introduction: Validated models describing the biomechanics of tooth extraction are scarce. This study seeks to perform experimental and numerical characterization of vertical tooth extraction biomechanics in swine incisors with imposed vertical extraction loads. Imaging analysis related mechanical outcomes to tooth geometry and applied loading rate.

View Article and Find Full Text PDF

Terahertz (THz) generation via photomixing on photoconductive antenna using twin delayed chirped pulses provides a long THz pulse with a narrow bandwidth. To generate a long pulse with a broad bandwidth, we propose a new, to the best of our knowledge, method that combines two long optical pulses with opposite chirps. The pulses exhibit temporal distributions of their instantaneous frequencies with opposite slopes.

View Article and Find Full Text PDF

Acrobatics at the insect scale: A durable, precise, and agile micro-aerial robot.

Sci Robot

January 2025

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA.

Aerial insects are exceptionally agile and precise owing to their small size and fast neuromotor control. They perform impressive acrobatic maneuvers when evading predators, recovering from wind gust, or landing on moving objects. Flapping-wing propulsion is advantageous for flight agility because it can generate large changes in instantaneous forces and torques.

View Article and Find Full Text PDF

Rate of torque development (RTD) measures how rapidly one can generate torque and is crucial for balance and athletic performance. Fast RTD depends on the rapid recruitment of high threshold motor units (MUs). Cutaneous electrical stimulation has been shown to alter MU excitability, favoring high threshold MUs via reduced recruitment thresholds.

View Article and Find Full Text PDF

Understanding sleep stages is crucial for diagnosing sleep disorders, developing treatments, and studying sleep's impact on overall health. With the growing availability of affordable brain monitoring devices, the volume of collected brain data has increased significantly. However, analyzing these data, particularly when using the gold standard multi-lead electroencephalogram (EEG), remains resource-intensive and time-consuming.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!