Our study reports a sub-group of patients with developmental dysplasia from a previously published larger series, with particular emphasis on the use of the uncemented RM acetabular component. We evaluated the long term results of 93 consecutive uncemented THAs in 80 patients using the titanium-coated RM acetabular component and the CLS femoral component in a prospective study. Eighteen hips in 16 patients had osteoarthritis secondary to developmental dysplasia of the hip. The mean follow-up was 19.6 years (18.2 to 20.9). Fourteen patients with 15 hips were clinically and radiographically examined and evaluated. Two patients with 3 hips died. No patient was lost to follow-up. No implant had to be revised, and no cases showed evidence of radiographic loosening. Nine acetabular components were not completely covered by host bone but this did not affect the outcome. At the latest follow-up the mean Harris Hip Score was 92 (81 to 100). The mean annual wear rate was 0.12 mm. The RM acetabular component performed well over 20 years in this selected group of patients. Complete acetabular containment was not needed, thus allowing reliable reconstruction of the anatomical centre of rotation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/112070001002000114DOI Listing

Publication Analysis

Top Keywords

acetabular component
16
uncemented acetabular
8
developmental dysplasia
8
patients hips
8
acetabular
6
patients
6
component
5
treatment acetabular
4
acetabular dysplasia
4
dysplasia uncemented
4

Similar Publications

Background: Periprosthetic hip dislocation after total hip arthroplasty is a devastating postoperative complication. It is often associated with suboptimal orientation of the acetabular component, characterized by the acetabular abduction and anteversion angles obtained from anteroposterior pelvic radiographs. We introduce a novel automated web tool to streamline the subjective and lengthy process of this manual measurement and compare it to manual human measurements.

View Article and Find Full Text PDF

Dislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.

View Article and Find Full Text PDF

Several studies suggested that total hip arthroplasty (THA) was more technical demanding following previous pelvic osteotomy (PO), resulting in poor outcomes compared with primary THA. However, the other studies regarding this topic had reported contradictory results. Therefore, we conducted this meta-analysis to compare the clinical results and other parameters between total hip arthroplasty following pelvic osteotomy and primary total hip arthroplasty.

View Article and Find Full Text PDF

Large-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.

View Article and Find Full Text PDF

Background: The ideal anteversion at which the acetabular and femoral components for a total hip arthroplasty (THA) should be implanted is still a subject of debate. One alignment philosophy being explored is restoration of individual constitutional femoral and acetabular anteversion. This study aimed to measure combined anteversion in a healthy hip population and understand the expected phenotypes and ranges for constitutional hip alignment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!