Patterning is of paramount importance in many areas of modern science and technology. As a good candidate for novel nanoscale optoelectronics and miniaturized molecule sensors, vertically aligned silicon nanowire (SiNW) with controllable location and orientation is highly desirable. In this study, we developed an effective procedure for the fabrication of vertically aligned SiNW arrays with micro-sized features by using single-step photolithography and silver nanoparticle-induced chemical etching at room temperature. We demonstrated that the vertically aligned SiNW arrays can be used as a platform for label-free DNA detection using surface-enhanced Raman spectroscopy (SERS), where the inherent "fingerprint" SERS spectra allows for the differentiation of closely related biospecies. Since the SiNW array patterns could be modified by simply varying the mask used in the photolithographic processing, it is expected that the methodology can be used to fabricate label-free DNA microarrays and may be applicable to tissue engineering, which aims to create living tissue substitutes from cells seeded onto 3D scaffolds.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-010-3889-z | DOI Listing |
Materials (Basel)
December 2024
The Building Technology Department, Linnæus University, 352 52 Växjö, Sweden.
Timber-concrete composites are established structural elements to combine the advantageous properties of both materials by connecting them. In this work, an innovative flexible adhesive connection in different configurations is investigated. Load-bearing capacity, stiffness, and the failure modes were first experimentally investigated by performing push-out tests.
View Article and Find Full Text PDFNeurospine
December 2024
Department of Orthopedic Surgery, Haeundae Bumin Hospital, Busan, Korea.
Objective: To identify the risk factors for proximal junctional failure (PJF) after adult spinal deformity (ASD) surgery despite ideal sagittal correction according to age-adjusted alignment target.
Methods: The study included patients who underwent low thoracic to pelvic fusion for ASD and obtained ideal correction according to age-adjusted pelvic incidence minus lumbar lordosis. PJF was defined either radiographically as a proximal junctional angle (PJA) of >28° plus a difference in PJA of >22° or clinically as revision surgery for proximal junctional complications.
Clin Spine Surg
January 2025
Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
N Am Spine Soc J
December 2024
Department of Neurosurgery, Warren Alpert Medical School of Brown University, Providence, RI, United States.
Background: Previous research on spinal alignment and postoperative outcomes after cervical and upper thoracic fixation has suggested that clinical and patient-reported outcomes are improved when certain anatomical parameters are maintained. These parameters include the cervical sagittal vertical axis (cSVA), C2 and T1 slopes, and cervical lordosis (CL). For patients with primary and metastatic tumors involving the subaxial cervical and/or upper thoracic spine, there is minimal guidance on how to apply these parameters.
View Article and Find Full Text PDFACS Omega
December 2024
School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD, U.K.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!