Background: Permanent pacing (PM) in patients with congenital heart disease (CHD) presents unique challenges-with little known about the long-term outcomes.
Methods: Pacemaker complications and reinterventions were reviewed over a 38-year period and were grouped by epicardial or endocardial approaches.
Results: The average age at intervention was 37 ± 19 years for 106 patients and 259 PM procedures were performed (2.4 ± 2 per patient). From the first PM procedure, patients were followed for 11.6 ± 14 years. The most common indications for initial PM intervention were heart block (25%) and sinus node dysfunction (20%), yet reintervention was driven primarily by lead failure (49%). Endocardial systems were initially implanted in 73 patients (67%). Epicardial pacing was more common in patients with complex CHD (p = 0.006), cyanosis (p < 0.001), residual shunts (0.01), or Ebstein's anomaly (p = 0.01). Fifty-one devices (28%) developed lead or generator complications. Epicardial systems were most likely to develop lead failure (p < 0.0001), predominantly in the ventricular lead (p < 0.0001). Endocardial systems were found to be more durable than the epicardial systems (p = 0.023), and Ebstein's anomaly or an epicardial system was an independent predictor of lead failure.
Conclusions: Permanent pacing in CHD is associated with considerable morbidity and the need for repeat intervention, especially in those with Ebstein's anomaly. Epicardial pacing systems appear to have a higher incidence of lead failure and are significantly less durable in this group.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-010-9494-4 | DOI Listing |
Micromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFHealthcare (Basel)
January 2025
Methodology, Methods, Models and Outcomes of Health and Social Sciences (M3O) Research Group, Faculty of Health Sciences and Welfare, Centre for Health and Social Care Research, University of Vic-Central University of Catalonia (UVIC-UCC), 08500 Vic, Spain.
In today's fast-paced work environment, work engagement is crucial for both organizational success and individual well-being. Our aim is this study was to analyze the associated factors of work engagement, work overload, work satisfaction, and emotional exhaustion and describe their effect on nurses and physicians in the Central Catalonia Health Region during 2023. A multicenter cross-sectional study was conducted using an online questionnaire at the Territorial Management of Central Catalonia (Spain).
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
JACC Clin Electrophysiol
January 2025
Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, California, USA; Metro Health Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA; Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy. Electronic address:
Background: Earlier studies have documented the risk for sinoatrial node injury and phrenic nerve paralysis as complications following radiofrequency catheter ablation for electrical isolation of the superior vena cava (SVCI).
Objectives: The aim of this study was to assess the safety and feasibility of SVCI in patients with atrial fibrillation undergoing pulsed field ablation (PFA) METHODS: Six hundred sixteen consecutive patients undergoing PFA for pulmonary vein isolation plus SVCI were included in this multicenter analysis. Superior vena cava (SVC) ablation was performed under the continuous guidance of intracardiac echocardiography.
Oxf Med Case Reports
January 2025
Department of Cardiology, Aga Khan Hospital, Barack Obama road, Upanga, Dar Es Salaam, Tanzania.
There is an increased risk of cardiac complications in COVID-19 among patients with pre-existing comorbidities due to their existing pro-inflammatory status. The manifestation of complete heart block has been evidenced as transient and in no need of intervention. This case presents a previously healthy woman who was diagnosed with SARS-CoV-2 infection and complete heart block; she underwent permanent dual-chamber pacemaker implantation after successful treatment and a negative COVID-19 test.