Summary We compared the performance of the Intersurgical Solus laryngeal mask airway (LMA) with that of the i-gel in 120 patients of ASA physical status during general anaesthesia with respect to oropharyngeal leak pressure, peak airway pressure, airway manipulation, insertion time, fibreoptic view, ventilatory parameters, and peri-operative complications. After receiving a standardised induction of anaesthesia, either a Solus LMA (60 patients) or an i-gel (60 patients) was inserted. One hundred and fifteen patients completed the study. The leak pressure was significantly higher in the LMA group than the i-gel group (mean (SD) 22.7 (7.7) cmH(2)O vs 19.3 (7.1) cmH(2)O; p = 0.02). A better fibreoptic view of the larynx was obtained in patients in the LMA group (p = 0.02) compared to those in the i-gel group and less airway manipulation was required in the LMA group (p < 0.01). Both devices have good performance with very low peri-operative complications. However, the Solus LMA provides a better oropharyngeal seal, provides a better fibreoptic view, and requires less manipulation to secure the airway than the i-gel.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1365-2044.2010.06336.x | DOI Listing |
Front Med (Lausanne)
December 2024
Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, Łódź, Poland.
Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.
View Article and Find Full Text PDFTransl Vis Sci Technol
December 2024
Department of Ophthalmology & Vision Sciences, University of Toronto, Toronto, ON, Canada.
Purpose: To demonstrate that high-seed, ultra-high-resolution spectral-domain optical coherence tomography (SD-OCT) technology can image in vivo fine morphological features in the healthy and pathological human limbus.
Methods: A compact, fiberoptic SD-OCT system was developed for imaging the human limbus. It combines ∼1.
J Thorac Dis
November 2024
Department of Anesthesiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Centre for Specialty Strategy Research of Shanghai Jiao Tong University China Hospital Development Institute, Shanghai, China.
Eur Arch Otorhinolaryngol
December 2024
Department of Otorhinolaryngology, Head and Neck Surgery, AIIMS, New Delhi, India.
Background: Direct laryngoscopy and biopsy have been the standard of care for biopsy of lesions arising from the upper aerodigestive tract (UADT). The requirement of general anesthesia is often a prerequisite. Procedures performed under the laryngeal block and local anesthesia are not viewed as appropriate from the point of view of patient comfort.
View Article and Find Full Text PDFSensors (Basel)
October 2024
Institute of Applied Physics, Military University of Technology, 00-908 Warsaw, Poland.
This article reviews rotational seismology, considering different areas of interest, as well as measuring devices used for rotational events investigations. After a short theoretical description defining the fundamental parameters, the authors summarized data published in the literature in areas such as the indirect numerical investigation of rotational effects, rotation measured during earthquakes, teleseismic wave investigation, rotation induced by artificial explosions, and mining activity. The fundamental data on the measured rotation parameters and devices used for the recording are summarized and compared for the above areas.