Comparison of the Intersurgical Solus laryngeal mask airway and the i-gel supralaryngeal device.

Anaesthesia

Department of Anesthesiology and Critical Care, Zahedan University of Medical Sciences, Zahedan, Iran.

Published: August 2010

Summary We compared the performance of the Intersurgical Solus laryngeal mask airway (LMA) with that of the i-gel in 120 patients of ASA physical status during general anaesthesia with respect to oropharyngeal leak pressure, peak airway pressure, airway manipulation, insertion time, fibreoptic view, ventilatory parameters, and peri-operative complications. After receiving a standardised induction of anaesthesia, either a Solus LMA (60 patients) or an i-gel (60 patients) was inserted. One hundred and fifteen patients completed the study. The leak pressure was significantly higher in the LMA group than the i-gel group (mean (SD) 22.7 (7.7) cmH(2)O vs 19.3 (7.1) cmH(2)O; p = 0.02). A better fibreoptic view of the larynx was obtained in patients in the LMA group (p = 0.02) compared to those in the i-gel group and less airway manipulation was required in the LMA group (p < 0.01). Both devices have good performance with very low peri-operative complications. However, the Solus LMA provides a better oropharyngeal seal, provides a better fibreoptic view, and requires less manipulation to secure the airway than the i-gel.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2044.2010.06336.xDOI Listing

Publication Analysis

Top Keywords

fibreoptic view
12
lma group
12
intersurgical solus
8
solus laryngeal
8
laryngeal mask
8
mask airway
8
airway i-gel
8
leak pressure
8
airway manipulation
8
peri-operative complications
8

Similar Publications

Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.

View Article and Find Full Text PDF

Purpose: To demonstrate that high-seed, ultra-high-resolution spectral-domain optical coherence tomography (SD-OCT) technology can image in vivo fine morphological features in the healthy and pathological human limbus.

Methods: A compact, fiberoptic SD-OCT system was developed for imaging the human limbus. It combines ∼1.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates two methods of bronchial blocker (BB) placement for lung isolation during thoracic surgery: electromagnetic navigation bronchoscopy (ENB) and fiberoptic bronchoscopy (FOB).
  • It found that ENB-guided technique resulted in better subjective lung collapse scores and required significantly less time for correct BB placement compared to the FOB method.
  • Despite these advantages, other factors like the incidence of malposition and patient vitals showed no significant differences between the two techniques.
View Article and Find Full Text PDF

Office-based flexible endoscopic guided biopsy: single-center feasibility analysis.

Eur Arch Otorhinolaryngol

December 2024

Department of Otorhinolaryngology, Head and Neck Surgery, AIIMS, New Delhi, India.

Background: Direct laryngoscopy and biopsy have been the standard of care for biopsy of lesions arising from the upper aerodigestive tract (UADT). The requirement of general anesthesia is often a prerequisite. Procedures performed under the laryngeal block and local anesthesia are not viewed as appropriate from the point of view of patient comfort.

View Article and Find Full Text PDF

This article reviews rotational seismology, considering different areas of interest, as well as measuring devices used for rotational events investigations. After a short theoretical description defining the fundamental parameters, the authors summarized data published in the literature in areas such as the indirect numerical investigation of rotational effects, rotation measured during earthquakes, teleseismic wave investigation, rotation induced by artificial explosions, and mining activity. The fundamental data on the measured rotation parameters and devices used for the recording are summarized and compared for the above areas.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!