Background: Transinguinal sonography can be used to demonstrate the position of the femoral head after reduction of a dislocated hip.
Objective: To determine whether transinguinal sonography can replace radiography and CT in the follow-up after reduction of a hip dislocation?
Materials And Methods: Thirty-three children with 39 dislocated hips were followed up with sonography after reduction and immobilization in a spica cast. In cases of an abnormal position a CT scan was advised. A pelvic radiograph at the end of treatment served as an indicator that no dislocations were missed during the previous sonographic examinations.
Results: The repositioned hips were examined on 138 occasions. Twenty-four examinations were abnormal and CT scanning was performed on 11 occasions. In four children additional CT was done because a recurrent dislocation was suspected or because sonography was difficult to perform. No dislocations were demonstrated. In five children a recurrent dislocation was suspected, on one or more occasions. In all but one child a CT scan was performed that confirmed the dislocation.
Conclusion: Transinguinal sonography is well-suited to demonstrate a normal position of the femoral head in a spica cast. Transinguinal sonography decreases the number of radiographs and CT scans and reduces the exposure to ionizing radiation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2950267 | PMC |
http://dx.doi.org/10.1007/s00247-010-1726-3 | DOI Listing |