The potential for undertaking slow CT using a modern CT scanner.

Br J Radiol

Northern Ireland Cancer Centre, Belfast City Hospital, Belfast Health and Social Care Trust, Lisburn Road, Belfast, UK.

Published: August 2010

Respiratory motion complicates target volume definition for patients with lung cancer. The use of slow CT to aid in the definition of moving target volumes was investigated. Standard and slow scans of an oscillating phantom were acquired using gantry rotation periods of 0.8 and 1.5 s and pitches of 0.95 and 0.50, respectively. The resultant images of three spheres within the phantom, labelled as A, B and C with diameters of 3.7, 2.8 and 2.2 cm, were analysed. The central co-ordinates of each volume were determined, and the ratio of the target volume outlined on CT (TV(CT)) to the true target volume (TV) was calculated. For 1.5 cm peak-to-trough (PTT) motion, standard CT mean ratios of 0.8, 0.8 and 0.7 were obtained for spheres A, B and C, respectively, whereas slow CT resulted in a mean ratio of 0.9 for all three spheres. For 2.5 cm motion, standard CT mean ratios of 0.8, 0.7 and 0.7 were obtained, whereas the slow CT mean ratios were 0.9, 0.9 and 0.8. The deviation of the central co-ordinate for the slow CT volumes was within 0.1 cm whereas deviations of up to 0.7 cm were seen using standard CT. This study indicates the potential benefit of using slow CT, even on modern scanners capable of rotation periods only down to 1.5 s, to define moving target volumes more accurately and reproducibly moving target volumes, and aid in the management of respiratory motion for patients with lung cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3473507PMC
http://dx.doi.org/10.1259/bjr/31551018DOI Listing

Publication Analysis

Top Keywords

target volume
12
moving target
12
target volumes
12
slow modern
8
respiratory motion
8
patients lung
8
lung cancer
8
rotation periods
8
three spheres
8
motion standard
8

Similar Publications

Resistance training (RT) load and volume are considered crucial variables to appropriately prescribe and manage for eliciting the targeted acute responses (i.e., minimizing neuromuscular fatigue) and chronic adaptations (i.

View Article and Find Full Text PDF

Introduction: The core objective of this study was to precisely locate metastatic lymph nodes, identify potential areas in nasopharyngeal carcinoma patients that may not require radiotherapy, and propose a hypothesis for reduced target volume radiotherapy on the basis of these findings. Ultimately, we reassessed the differences in dosimetry of organs at risk (OARs) between reduced target volume (reduced CTV2) radiotherapy and standard radiotherapy.

Methods And Materials: A total of 209 patients participated in the study.

View Article and Find Full Text PDF

High-affinity VNARs targeting human hemoglobin: Screening, stability and binding analysis.

Int J Biol Macromol

January 2025

College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China. Electronic address:

Hemoglobin, composed of α- and β-chains, is essential for oxygen transport and is key in diagnosing and treating gastrointestinal and blood disorders. It also aids in detecting blood contamination and estimating transfusion volumes. Immunological methods, based on antigen-antibody interactions, are distinguished by their high sensitivity and accuracy.

View Article and Find Full Text PDF

As the volume of plastic waste from electrical and electronic equipment (WEEE) continues to rise, a significant portion is disposed of in the environment, with only a small fraction being recycled. Both disposal and recycling pose unknown health risks that require immediate attention. Existing knowledge of WEEE plastic toxicity is limited and mostly relies on epidemiological data and association studies, with few insights into the underlying toxicity mechanisms.

View Article and Find Full Text PDF

Development and validation of a high-performance liquid chromatography method with fluorescence detection for the quantification of the resistance protein P-gp in cancer cells.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Université Clermont Auvergne, Institut Universitaire de Technologie, UMR INSERM-UCA, U1240, Imagerie Moléculaire et Stratégies Théranostiques (IMoST), 5 Avenue Blaise Pascal, 63000 Clermont-Ferrand, France.

A method using high-performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) was developed and validated to quantify the innovative tool LightSpot®-FL-1, a selective permeability-glycoprotein (P-gp)-targeted fluorescent conjugate used to measure P-gp expression in cell samples. Quantifying P-gp is a major challenge in oncology as its overexpression in many cancer cells results in Multidrug Resistance (MDR) associated with chemotherapy failure. To develop the method reported herein, both sample preparation and analysis parameters were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!