As part of a cross-sectional study of aging of the human accommodative apparatus, unaccommodated anterior chamber depth, unaccommodated lens thickness, and accommodative amplitude were each determined by two or more independent techniques in 100 normal emmetropic subjects, age 18-70 yr. For anterior chamber depth, the order of accuracy seemed to be: optical pachymetry > slit-lamp Scheimpflug photography > Ascan ultrasonography, although there was good agreement among all three methods. For lens thickness, slitlamp Scheimpflug photography seemed more accurate than A-scan ultrasonography when the generally accepted lenticular sound velocity of 1641 m . s(-1) was used for the ultrasonographic calculation. The agedependent divergence allowed calculation of a putative relationship between lenticular sound velocity and age, indicating that velocity decreased by ~3 m . s(-1) . yr(-1). Accommodative amplitude declined with age, reaching a minimum, by age 50 yr, of 0.5 diopters as measured by coincidence refractometry. This residual 0.5 diopters may represent the inherent focal depth of the eye's optical system, rather than active accommodation. Maximum accommodative amplitude based on the subject's ability to clearly visualize a target through minus lenses was always 1.50 diopters greater than the refractometrically measured maximum, regardless of age. This difference presumably represents increased depth of field provided by pupillary constriction, rather than active accommodation.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.28.001097DOI Listing

Publication Analysis

Top Keywords

accommodative amplitude
12
anterior chamber
8
chamber depth
8
lens thickness
8
scheimpflug photography
8
lenticular sound
8
sound velocity
8
active accommodation
8
age
5
accommodation presbyopia
4

Similar Publications

Purpose To investigate changes in accommodation amplitude (AA) after strabismus surgery. Methods The medical records of patients who underwent full-tendon tenotomy on at least one rectus muscle between January 2023 and July 2023 were reviewed retrospectively. AA was evaluated objectively and monocularly with the autorefractometry (Tonoref III, ARK-1a, NIDEK Co Ltd, Gamagori, Japan).

View Article and Find Full Text PDF

Dynamic Accommodation Responses in Subjects Wearing Myopia Control Spectacles Modifying Peripheral Refraction.

Invest Ophthalmol Vis Sci

January 2025

Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain.

Purpose: Peripheral optics have been suggested to play a role in myopia progression, with accommodation responses also considered a potential contributor. This study aimed to investigate whether modifications in peripheral optics through different spectacle lenses affect accommodation responses.

Methods: Dynamic accommodation responses were assessed using a double-pass instrument while switching the target from distance (3 m for 3 seconds) to near (0.

View Article and Find Full Text PDF

The difference in accommodative amplitude and facility between the dominant and non-dominant eyes.

J Pak Med Assoc

January 2025

Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.

The cross-sectional study was planned to compare the amplitude of accommodation and accommodative facility between the dominant and non-dominant eyes in young university students. The sample comprised 70 healthy young adult students at King Saud University, Saudi Arabia, who were aged 19-27 years with a mean of 21.46±1.

View Article and Find Full Text PDF

Objective: To evaluate the therapeutic effects of Visual Training System 4 (VTS4) as an adjunctive therapy for patients with refractive amblyopia.

Method: A total of 82 patients with refractive amblyopia (142 eyes) treated at the Zhongshan Ophthalmic Center of Sun Yat-sen University, were enrolled and divided into two groups based on the treatment protocol. The control group included 40 patients (68 eyes) who received conventional comprehensive treatment, while the observation group was comprised of 42 patients (74 eyes) treated with VTS4 in addition to conventional therapy.

View Article and Find Full Text PDF

We present a non-interferometric technique for quantitative phase imaging (QPI) that is cost-effective, easily integrated into standard microscopes, and capable of wide-field imaging with noncoherent light. Our method measures the phase gradient through optical differentiation using spatially variable amplitude filters, accommodating a range of transmission functions, including commercially available variable neutral-density filters. This flexibility is made possible by a general relationship we derive.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!