AI Article Synopsis

  • The text discusses a technique for coherently adding laser pulses to enhance intensity in the laser far field, particularly using a tiled grating in a laser-pulse compressor.
  • It highlights the previously encountered issue where variations in grating constants between phased gratings limited intensity output.
  • The proposed method improves the alignment process of the tiled grating compressor, enabling more effective coherent addition of the laser pulses.

Article Abstract

We describe a method that can be used for the coherent addition of laser pulses. As different laser pulses are initially generated in a laser-pulse compressor equipped with a tiled grating, such a coherent addition is indispensable in order to maximize the intensity in the laser far field. We present measurements in this context where, up to now, an unavoidable difference in the grating constants between the phased gratings reduced the maximum achievable intensity. The method significantly facilitates the high-precision alignment of a tiled grating compressor and could also be used for a coherent addition of laser pulses.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.35.002073DOI Listing

Publication Analysis

Top Keywords

coherent addition
16
laser pulses
16
addition laser
12
tiled grating
12
grating compressor
8
laser
5
spectrally resolved
4
resolved phase-sensitive
4
phase-sensitive far-field
4
far-field measurement
4

Similar Publications

Purpose: To quantitatively explore preretinal abnormal tissue (PAT) in macula-on rhegmatogenous retinal detachment (RRD) before and after surgery.

Methods: In this case-series study, PAT was detected by en-face optical coherence tomography images with custom slabs in eyes that underwent pars plana vitrectomy and SF6 for macula-on RRD.Main outcome measures were PAT area at baseline, 3-month and 6-month follow-up, and its relative change.

View Article and Find Full Text PDF

Basic Science and Pathogenesis.

Alzheimers Dement

December 2024

The Jackson Laboratory, Bar Harbor, ME, USA.

Background: Mechanisms driving cerebrovascular decline during Alzheimer's disease and related dementias (ADRD) are poorly understood. Methylenetetrahydrofolate reductase (MTHFR) is an enzyme in the folate/methionine pathway. Variants in MTHFR, notably 677C>T, are associated with ADRD.

View Article and Find Full Text PDF

Designing Hybrid Plasmonic Superlattices with Spatially Confined Responsive Heterostructural Units.

Nano Lett

January 2025

State Key Laboratory of Solidification Processing, Center of Advanced Lubrication and Seal Materials, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, P.R. China.

Plasmonic superlattices enable the precise manipulation of electromagnetic fields at the nanoscale. However, the optical properties of static lattices are dictated by their geometry and cannot be reconfigured. Here, we present a surface-interface engineered plasmonic superlattice with confined polyelectrolyte-functionalized metal-organic framework (MOF) hybrid layers to tune plasmon resonance for ultrafast chemical sensing.

View Article and Find Full Text PDF

Current dorsal skin flap window chambers with flat glass windows are compatible with optical coherence tomography (OCT) and multiphoton microscopy (MPM) imaging. However, light sheet fluorescence microscopy (LSFM) performs best with a cylindrical or spherical sample located between its two 90° objectives and when all sample materials have the same index of refraction (). A modified window chamber with a domed viewing window made from fluorinated ethylene propylene (FEP), with n similar to water and tissue, was designed.

View Article and Find Full Text PDF

Recent Advances in the Treatment of Coronary In-Stent Restenosis.

Rev Cardiovasc Med

December 2024

Department of Cardiology, Bern University Hospital, Inselspital, CH-3010 Bern, Switzerland.

In-stent restenosis (ISR) remains the predominant cause of stent failure and the most common indication for repeat revascularization. Despite technological advances in stent design, ISR continues to pose significant challenges, contributing to increased morbidity and mortality among patients undergoing percutaneous coronary interventions. In the last decade, intravascular imaging has emerged as an important method for identifying the mechanisms behind ISR and guiding its treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!