Objectives: The combination of parallel acquisition (generalized autocalibrating partially parallel acquisitions) and time-resolved three-dimensional (3D) view-sharing techniques is a promising tool for dynamic contrast-enhanced 3D-magnetic resonance angiography (MRA). We evaluated the influence of different k-space acquisition strategies on image quality for a recently developed time-resolved echo-shared angiographic technique during a contrast-enhanced 3D-MRA of the thoracic vessels.

Materials And Methods: In 20 patients (16 men, 4 women; range, 28-75 years), 2 dynamic MRA protocols with different k-space acquisition strategies were performed on a 1.5-T whole-body scanner (MAGNETOM Avanto, Siemens AG, Erlangen, Germany) during injection of 5 mL (flow-rate, 3 mL/s) gadobutrol. For protocol 1, the central-region which was updated with every cycle included 20% of the entire k-space (protocol 2: 10%), the peripheral-region was undersampled by a factor of 10 (protocol 2: 5%). Image quality and details were compared visually. Signal-to-noise ratio and sharpness of vessel borders were estimated.

Results: Morphologic and functional assessment of the pulmonary arteries and the aorta was significantly improved for protocol 1. The sharpness of vessel borders (3.3 mm vs. 4.1 mm; P = 0.001), image quality, and the visibility of image details were significantly improved for protocol 1 compared with protocol 2.

Conclusion: The size of the central region that is updated for every frame seems to be more crucial for image quality of echo-shared angiographic techniques than the sampling density in the periphery of the k-space.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0b013e3181e5bbb0DOI Listing

Publication Analysis

Top Keywords

image quality
16
k-space acquisition
12
acquisition strategies
12
dynamic contrast-enhanced
8
resonance angiography
8
echo-shared angiographic
8
sharpness vessel
8
vessel borders
8
improved protocol
8
protocol
6

Similar Publications

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

CNN is considered an efficient tool in brain image segmentation. However, neonatal brain images require specific methods due to their nature and structural differences from adult brain images. Hence, it is necessary to determine the optimal structure and parameters for these models to achieve the desired results.

View Article and Find Full Text PDF

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.

View Article and Find Full Text PDF

Nutrient deprivation is a major trigger of autophagy, a conserved quality control and recycling process essential for cellular and tissue homeostasis. In a high-content image-based screen of the human ubiquitome, we here identify the E3 ligase Pellino 3 (PELI3) as a crucial regulator of starvation-induced autophagy. Mechanistically, PELI3 localizes to autophagic membranes, where it interacts with the ATG8 proteins through an LC3-interacting region (LIR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!