A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated segmentation of optic disc region on retinal fundus photographs: Comparison of contour modeling and pixel classification methods. | LitMetric

Automated segmentation of optic disc region on retinal fundus photographs: Comparison of contour modeling and pixel classification methods.

Comput Methods Programs Biomed

Department of Intelligent Image Information, Graduate School of Medicine, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan.

Published: January 2011

The automatic determination of the optic disc area in retinal fundus images can be useful for calculation of the cup-to-disc (CD) ratio in the glaucoma screening. We compared three different methods that employed active contour model (ACM), fuzzy c-mean (FCM) clustering, and artificial neural network (ANN) for the segmentation of the optic disc regions. The results of these methods were evaluated using new databases that included the images captured by different camera systems. The average measures of overlap between the disc regions determined by an ophthalmologist and by using the ACM (0.88 and 0.87 for two test datasets) and ANN (0.88 and 0.89) methods were slightly higher than that by using FCM (0.86 and 0.86) method. These results on the unknown datasets were comparable with those of the resubstitution test; this indicates the generalizability of these methods. The differences in the vertical diameters, which are often used for CD ratio calculation, determined by the proposed methods and based on the ophthalmologist's outlines were even smaller than those in the case of the measure of overlap. The proposed methods can be useful for automatic determination of CD ratios.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2010.04.006DOI Listing

Publication Analysis

Top Keywords

optic disc
12
segmentation optic
8
retinal fundus
8
methods automatic
8
automatic determination
8
disc regions
8
proposed methods
8
methods
7
automated segmentation
4
disc
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!