Development and validation of a liquid chromatography-mass spectrometry assay for the quantitation of IPTG in E. Coli fed-batch cultures.

Anal Chem

Departament d'Enginyeria Química, Escola d'Enginyeria, Unitat de Biocatàlisi Aplicada associada al IQAC (CSIC), Universitat Autònoma de Barcelona, Edifici Q, 08193 Bellaterra (Cerdanyola del Vallés), Spain.

Published: July 2010

IPTG (Isopropyl-beta-d-1-thiolgalactopyranoside) is a gratuitous inducer commonly used for the overexpression of heterologous recombinant proteins in Escherichia coli. A reliable method has been developed for the determination of IPTG in E.coli fed-batch fermentation samples with a minimal sample treatment. Analysis was performed in single ion monitoring positive mode using ESI source. The extracted ion was 261 m/z and the retention time of IPTG was 12.4 min with a total run time in samples of 30 min. The flow was directed to mass spectrometer 11 min after the start of the run and diverted from mass spectrometer after 14.5 min in order to avoid interference of salts and other metabolites. The assay was validated for medium and intracellular matrices and linear calibration curves of 3 orders of magnitude were obtained (R(2) >or= 0.99). Quality control samples were analyzed and showed precision and accuracy within the limits according to FDA Guidelines for analytical method validation. Recovery for both matrices was between 95.8 and 113.5%. The limit of detection (LOD) was set at 0.02 microM being the 0.1% of the lowest IPTG concentration used for induction of recombinant protein overexpression. The developed procedure has been applied to determine the IPTG distribution profiles in medium and intracellular samples in high cell density induced cultures for the production of the recombinant protein rhamnulose-1-phosphate aldolase (RhuA).

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac100756mDOI Listing

Publication Analysis

Top Keywords

mass spectrometer
8
medium intracellular
8
recombinant protein
8
iptg
6
development validation
4
validation liquid
4
liquid chromatography-mass
4
chromatography-mass spectrometry
4
spectrometry assay
4
assay quantitation
4

Similar Publications

The current research presents novel LC-TQ-MS/MS and cost-effective UPLC methods intended for the accurate quantification of mefenamic acid-N-nitroso drug substance-related impurity-NDSRI (N-MFA) in mefenamic acid (MFA) tablet and pediatric suspension dosage forms. The acceptable intake of N-MFA is derived from the TD50 (Median Toxic Dose-50%) value of N-nitroso diphenylamine. The analytical separation was achieved for the UPLC method using an XBridge BEH Shield RP18 Column (150 × 3.

View Article and Find Full Text PDF

iDIA-QC: AI-empowered data-independent acquisition mass spectrometry-based quality control.

Nat Commun

January 2025

Affiliated Hangzhou First People's Hospital, State Key Laboratory of Medical Proteomics, School of Medicine, Westlake University, Hangzhou, Zhejiang Province, China.

Quality control (QC) in mass spectrometry (MS)-based proteomics is mainly based on data-dependent acquisition (DDA) analysis of standard samples. Here, we collect 2754 files acquired by data independent acquisition (DIA) and paired 2638 DDA files from mouse liver digests using 21 mass spectrometers across nine laboratories over 31 months. Our data demonstrate that DIA-based LC-MS/MS-related consensus QC metrics exhibit higher sensitivity compared to DDA-based QC metrics in detecting changes in LC-MS status.

View Article and Find Full Text PDF

The widespread occurrence of pesticides requires thorough evaluations of human population exposure to these chemicals, particularly children, because of the potential long-term effects of some of these neurotoxicants. The present study describes an in-depth screening of 15 pesticides including organophosphates, pyrethroids, carbamates, triazoles, neonicotinoids and their main metabolites. Internal exposure of 7-9-year-old children from urban and agricultural locations in Poland (n = 399) has been studied.

View Article and Find Full Text PDF

Development and validation of a UHPLC-MS/MS method for the quantitative analysis of trans-ISRIB in human plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Department of Chemistry, Cleveland State University, Cleveland, OH 44115, USA. Electronic address:

The integrated stress response (ISR) is a cellular defense mechanism activated under stress conditions. When the ISR is activated, it slows the production of proteins, the building blocks that cells need to function. Trans-integrated stress response inhibitor (trans-ISRIB) is a compound that can reverse the effects of ISR activation, showing promise for treating neurodegenerative diseases.

View Article and Find Full Text PDF

Mesh-Collision Microtube Plasma Ion Source for Direct Mass Spectrometry Analysis.

Anal Chem

January 2025

Chinese Academy of Inspection and Quarantine, Beijing 100176, China.

Developing ambient ionization methods for direct mass spectrometry (MS) analysis is crucial for achieving sample-to-answer capabilities, especially for rapid analysis and monitoring in specific scenarios. Herein, a compact device is presented that utilizes mesh-collision microtube plasma (MC-μTP) ionization for direct online MS analysis. This device features a self-aspirating design that enables the direct analysis of various sample types.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?