Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Spatially modulated imaging Fourier transform spectrometer (SMIFTS) was an instrument that depended on interference, and after calibration, the reconstruction spectrum can quantificationally reflect the diffuse reflection of target under sunshine. On-board calibration of SMIFTS confirmed the change of SMIFTS according to relative spectrum calibration, inspected long-time attenuation of SMIFTS optical system, and corrected export data of SMIFTS. According to the requirement of remote sensor application, it must stay in vacuum environment for a long time. As a radiant standard, the stability of lamp-house in long time is the most important characteristic of on-board calibration system. By calculation and experimentation, analyses of on-board calibration of SMIFTS, and testing spaceflight environment characteristic of on-board calibration, the difficulty in the key parts of on-board calibration of SMIFTS such as lamp-house, spectrum filter and integrating sphere was solved. According to the radiation-time stability testing for lamp-house and optics, particle-radiation testing, environmental-mechanics testing and hot vacuum examination, good result was obtained. By whole-aperture and part-field comparative wavelength calibration, the spectrum curve and before-launch interferogram were obtained. After comparison with reconstruction spectrum under different condition, the stability and credibility of SMIFTS on-board calibration system was proved.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!