A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of cytosine arabinoside, daunorubicin and etoposide in human plasma. | LitMetric

Simultaneous determination of cytosine arabinoside, daunorubicin and etoposide in human plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

University of Copenhagen, Faculty of Pharmaceutical Sciences, Department of Pharmacology and Pharmacotherapy, Jagtvej 160, DK-2100 Copenhagen, Denmark.

Published: July 2010

A method for simultaneous bioanalysis of the three cytotoxic drugs cytosine arabinoside, daunorubicin and etoposide in human plasma was developed and validated. A HPLC method with ultra-violet and fluorescence detection, preceded by mixed-mode cation-exchange solid phase extraction sample preparation, was used for the quantification of the analytes. The assay was used for the simultaneous measurement of cytosine arabinoside, daunorubicin and etoposide with linearity in the ranges of 13-1500 ng/mL, 15-1000 ng/mL and 52.5-3500 ng/mL, respectively. The chromatographic run-time was 15.5 min. The overall precision (% relative standard deviation) was within 0.2-13.5% and the recovery ranged between 86.1% and 110.1% for the three drugs at all concentrations tested. Plasma samples were stable for at least two months when stored at -20 degrees C. The method was successfully applied to quantification of the three drugs in blood samples from patients undergoing induction treatment for acute myeloid leukaemia, thus demonstrating its suitability for clinical studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2010.05.031DOI Listing

Publication Analysis

Top Keywords

cytosine arabinoside
12
arabinoside daunorubicin
12
daunorubicin etoposide
12
etoposide human
8
human plasma
8
three drugs
8
simultaneous determination
4
determination cytosine
4
plasma method
4
method simultaneous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!